TROUBLESHOOTING CHART

Symptom
Pump will not start or run
Pump will not prime or retain prime after
operating
Flow rate is too low
Shaft seal leaks
www.waynepumps.com
Possible Cause(s)
1. Blown fuse
2. Low line voltage
3. Worn brushes
4. Impeller blocked
5. Motor has overheated (Model PC2 only)
1. Air leak in suction line
2. Impeller blocked
3. Worn seal
4. Suction lift too high
5. Hose kinked or looped
6. Fittings not tight
7.
Suction hose out of water
8. Clogged inlet
1. Inlet hose plugged or kinked
2. Low line voltage
1. Worn seal
2. Shaft grooved
3. Pump head loose on motor
4
Corrective Action
1. If blown, replace with proper sized fuse or reset
breaker
2. Voltage of power supply must match the voltage
of the pump
3. Replace brushes (PC2 Only)
4. Remove blockage
5. Disconnect from power supply and allow to cool
(Minimum 10 minutes)
1. Repair suction line by tightening inlet connection
or replace
2. Remove blockage
3. Replace seal
4. Lower pump
5. Straighten hose
6. Tighten fittings
7. Submerge suction hose end
8. Clean inlet
1. Clean or replace
2. Voltage of power supply must match the voltage
of the pump
1. Replace seal
2. Replace pump
3. Insure proper assembly and no obstruction,
tighten bolts