OPERATING INSTRUCTIONS & PARTS MANUAL
UNPACKING
Inspect this unit before it is used. Occasionally, products are damaged during
shipment. If the pump or components are damaged, return the unit
to the place of purchase for replacement, or call Customer Support
(800-237-0987).
SAFETY SIGNAL WORDS
This manual contains information that is very important to know and
understand. This information is provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help recognize this information, observe
the following symbols.
Danger indicates an imminently hazardous situation which,
if NOT avoided, WILL result in death or serious injury.
La mention Danger indique une situation dangereuse
imminente qui, si elle n'est pas évitée, ENTRAÎNE la mort ou des blessures graves.
Warning indicates a potentially hazardous situation which,
if NOT avoided, COULD result in death or serious injury.
La mention avertissement indique une situation
potentiellement dangereuse qui, si elle n'est pas évitée, risque d'entraîner des lésions
corporelles graves ou même la mort.
Caution indicates a potentially hazardous situation which,
if NOT avoided, MAY result in minor or moderate injury.
MISE EN GARDE
La mention mise en garde indique une situation
potentiellement dangereuse qui, si elle n'est pas évitée, pourrait entraîner des
blessures mineures ou modérées.
Notice indicates important information, that if NOT
followed, MAY cause damage to equipment.
This is the safety alert symbol. It is used to alert you to potential
bodily injury hazards. Obey all safety messages that follow this
symbol to avoid possible harm.
NOTE: Information that requires special attention
If using pump to drain a vessel of water make sure the
pump is not used while people are in, or in-contact with the water.
Lors de l'utilisation de la pompe pour vider un réservoir
d'eau, s'assurer que personne ne se trouve dans ou en contact avec l'eau.
Do NOT pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, solvent, thinners, etc. DO NOT use in a flammable and/or
explosive atmosphere. ONLY pump clear water. Improper use could result in death or
serious injury, and will void warranty.
NE PAS pomper de liquides inflammables ou
explosifs tels que de l'essence, du mazout, du kérosène, des solvants, des
diluants, etc. NE PAS utiliser dans un environnement inflammable et/ou
explosive. Pomper UNIQUEMENT de l'eau claire. Une utilisation incorrect
peut pepeut entraîner la mort ou.
© 2020, WAYNE/Scott Fetzer Company.
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
protection against line to ground faults only. The ground fault receptacle does
NOT limit the magnitude of fault current and will NOT prevent electrical shock.
la terre fournira une protection uniquement contre les défauts entre les lignes
et les fuites à la terre. Le boîtier du disjoncteur de fuite à la terre ne limite PAS
l'amplitude du courant de défaut et n'empêchera PAS les chocs électriques.
installed, and grounded GFCI outlet in accordance with all applicable codes and
ordinances. Never remove the grounding prong or modify the plug in any way.
Do not use any adapter plugs. Check with a qualified electrician if you are not
sure the outlet is grounded. If the pump should electrically malfunction or break
down, grounding provides a low resistance path to carry electricity away from
the user.
correctement installée et une prise équipée d'un disjoncteur de fuite à la terre,
conformément à tous les codes et règlements applicables. Ne jamais retirer la
broche de mise à la terre et ne modifier, en aucun cas, la fiche. Ne pas utiliser
de prises d'adaptateur. Vérifier avec un électricien qualifié que la prise est bien
mise à la terre. Si la pompe présente un dysfonctionnement électrique ou une
panne, la mise à la terre fournit un chemin de faible résistance pour éloigner
l'électricité de l'utilisateur.
for damage. If damage is present DO NOT USE pump.
cordon d'alimentation et la prise ne sont pas endommagés. Si des dommages
sont présents, NE PAS UTILISER la pompe.
electrician. Improper wiring could result in fatal shock.
électricien qualifié. Un câblage incorrect peut entraîner un choc mortel.
suspend the pump or pull the plug from an outlet. Keep cord away from heat, oil,
sharp edges, or moving parts. Do not bury cord. Visually locate cord to prevent
damage. Damaged cords increase the risk of electrical shock and will void
warranty.
pour transporter la pompe ou tirer la fiche d'une prise de courant. Éloigner le
cordon de la chaleur, de l'huile, des arêtes vives ou des pièces mobiles. Les
cordons endommagés augmentent le risque de choc électrique et annuleront la
garantie.
on wet area until all power is turned off. If the shut-off box is in the basement,
call an electrician. Failure to follow this warning could result in fatal electrical
shock.
plancher, ne pas marcher aux endroits mouillés avant que le courant ne soit
coupé. Si le boîtier de coupure de courant se trouve au sous-sol, appeler
un électricien. Le non-respect de cet avertissement peut entraîner un choc
électrique morte.
www.waynepumps.com
WWB GLOW
Electric shock hazard! GFCI receptacles will provide
Risque de choc électrique! Le disjoncteur de fuite à
This pump must be plugged into a properly
Cette pompe doit être branchée dans une prise
Before each use inspect pump, power cord and plug
Avant chaque utilisation, vérifier que la pompe, le
Electrical wiring must be performed by a qualified
Le câblage électrique doit être réalisé par un
Do not abuse cord. Never use the cord to carry or
Prendre soin du cordon. Ne jamais utiliser le cordon
If there is water or moisture on the floor, do not walk
Si le sous-sol a de l'eau ou de l'humidité sur le
620011W-001 D 08/20

Advertisement

loading

Summary of Contents for Wayne WWB

  • Page 1 Si le boîtier de coupure de courant se trouve au sous-sol, appeler un électricien. Le non-respect de cet avertissement peut entraîner un choc électrique morte. © 2020, WAYNE/Scott Fetzer Company. www.waynepumps.com 620011W-001 D 08/20...
  • Page 2 Lors de l’entretien de cette pompe, seules des piéces de rechange originales de WAYNE doivent éure utilisées. Le non-respect de ces étapes Ce produit peutvous exposer à des produits chimiques, peut entrainer un risque d’inondation, de dégats matériels, de choc électrique mortel...
  • Page 3 Most electric product-related incidents are caused by feature can cause the pump to run dry and may damage the shaft seal and cause failure to observe basic safety rules or precautions. WAYNE Water Systems is NOT pump failure and void warranty.
  • Page 4: Quick Start Instructions

    Flat Roofs, Flooded Basements, standing water in yard, crawl spaces, etc. STEP 3 - REMOVE DISCHARGE CAP PLEASE SEE THE NEXT PAGE FOR STEPS 7-9 TWIST NOTE: Check/tighten unused discharge © 2020 , WAYNE/Scott Fetzer Company. For product & service information visit www.waynepumps.com...
  • Page 5 STEP 7 - PLUG WILL GLOW GREEN INDICATING THAT THE PUMP IS ON. STEP 8 - WHEN THE PUMP IS NO LONGER MOVING WATER IT WILL TURN OFF AFTER A PERIOD OF TIME AND THE PLUG INDICATOR WILL TURN RED. NOTE: At 70˚F this can take approximately 10 minutes.
  • Page 6 OPERATING INSTRUCTIONS & PARTS MANUAL GLOW ® WITH MOTOR SHUT-OFF PROTECTION CONSTRUCTION SPECIFICATIONS MOTOR HOUSING Thermoplastic POWER SUPPLY REQUIREMENTS 120 V, 60 Hz MOTOR SHAFT Stainless Steel MOTOR Single Phase, Dielectric Oil Filled HORSEPOWER 1/6 HP IMPELLER Thermoplastic CIRCUIT REQUIREMENT 15 A (minimum) PUMP DISCHARGE (2) 3/4 in.
  • Page 7: Pump Operation

    OPERATING INSTRUCTIONS & PARTS MANUAL DESCRIPTION 7. Always know where your discharge hose is placed. An unsecured discharge hose may move or whip when the This Submersible Multi-Use Pump is designed for non-automatic use pump is turned on. in clear water. The unit is equipped with a 10 meter, 3-prong grounding 8.
  • Page 8 OPERATING INSTRUCTIONS & PARTS MANUAL INLET SCREEN AND IMPELLER CLEANING a. Unplug pump from power source. b. Remove inner 6 screws shown in (Figure 1), do not remove the outer screws! c. Remove inlet screen and clean impeller and inlet screen of all debris.
  • Page 9: Troubleshooting Chart

    LIMITED WARRANTY For one year for ALL Submersible Utility Pump models from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser, any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.