Download Print this page

Wayne WWB AUTO Operating Instructions And Parts Manual

Advertisement

Quick Links

OPERATING INSTRUCTION AND PARTS MANUAL
UNPACKING
Inspect this unit before it is used. Occasionally, products are
damaged during shipment. If the pump or components are
damaged, return the unit to the place of purchase for replacement,
or call Customer Support (800-237-0987).
SAFETY SIGNAL WORDS
This manual contains information that is very important to know and
understand. This information is provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help recognize this information, observe
the following symbols.
Danger indicates an imminently hazardous situation which,
if NOT avoided, WILL result in death or serious injury.
La mention Danger indique une situation dangereuse
imminente qui, si elle n'est pas évitée, ENTRAÎNE la mort ou des blessures graves.
Warning indicates a potentially hazardous situation which,
if NOT avoided, COULD result in death or serious injury.
La mention avertissement indique une situation
potentiellement dangereuse qui, si elle n'est pas évitée, risque d'entraîner des lésions
corporelles graves ou même la mort.
Caution indicates a potentially hazardous situation which,
if NOT avoided, MAY result in minor or moderate injury.
MISE EN GARDE
potentiellement dangereuse qui, si elle n'est pas évitée, pourrait entraîner des
blessures mineures ou modérées.
Notice indicates important information, that if NOT
followed, MAY cause damage to equipment.
This is the safety alert symbol. It is used to alert you to potential
bodily injury hazards. Obey all safety messages that follow this
symbol to avoid possible harm.
NOTE: Information that requires special attention
If using pump to drain a vessel of water make sure the
pump is not used while people are in, or in-contact with the water.
Lors de l'utilisation de la pompe pour vider un réservoir
d'eau, s'assurer que personne ne se trouve dans ou en contact avec l'eau.
Do NOT pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, solvent, thinners, etc. DO NOT use in a
flammable and/or explosive atmosphere. ONLY pump clear water. Improper
use could result in death or serious injury, and will void warranty.
NE PAS pomper de liquides inflammables ou
explosifs tels que de l'essence, du mazout, du kérosène, des solvants,
des diluants, etc. NE PAS utiliser dans un environnement inflammable et/ou explosive.
Pomper UNIQUEMENT de l'eau claire. Une utilisation incorrect peut pepeut entraîner la
mort ou.
© 2020, WAYNE/Scott Fetzer Company.
La mention mise en garde indique une situation
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
protection against line to ground faults only. The ground fault receptacle does
NOT limit the magnitude of fault current and will NOT prevent electrical shock.
la terre fournira une protection uniquement contre les défauts entre les lignes
et les fuites à la terre. Le boîtier du disjoncteur de fuite à la terre ne limite PAS
l'amplitude du courant de défaut et n'empêchera PAS les chocs électriques.
installed, and grounded GFCI outlet in accordance with all applicable codes and
ordinances. Never remove the grounding prong or modify the plug in any way.
Do not use any adapter plugs. Check with a qualified electrician if you are not
sure the outlet is grounded. If the pump should electrically malfunction or break
down, grounding provides a low resistance path to carry electricity away from
the user.
correctement installée et une prise équipée d'un disjoncteur de fuite à la terre,
conformément à tous les codes et règlements applicables. Ne jamais retirer la
broche de mise à la terre et ne modifier, en aucun cas, la fiche. Ne pas utiliser
de prises d'adaptateur. Vérifier avec un électricien qualifié que la prise est bien
mise à la terre. Si la pompe présente un dysfonctionnement électrique ou une
panne, la mise à la terre fournit un chemin de faible résistance pour éloigner
l'électricité de l'utilisateur.
for damage. If damage is present DO NOT USE pump.
cordon d'alimentation et la prise ne sont pas endommagés. Si des dommages
sont présents, NE PAS UTILISER la pompe.
electrician. Improper wiring could result in fatal shock.
électricien qualifié. Un câblage incorrect peut entraîner un choc mortel.
suspend the pump or pull the plug from an outlet. Keep cord away from heat, oil,
sharp edges, or moving parts. Do not bury cord. Visually locate cord to prevent
damage. Damaged cords increase the risk of electrical shock and will void
warranty.
pour transporter la pompe ou tirer la fiche d'une prise de courant. Éloigner le
cordon de la chaleur, de l'huile, des arêtes vives ou des pièces mobiles. Les
cordons endommagés augmentent le risque de choc électrique et annuleront la
garantie.
on wet area until all power is turned off. If the shut-off box is in the basement,
call an electrician. Failure to follow this warning could result in fatal electrical
shock.
plancher, ne pas marcher aux endroits mouillés avant que le courant ne soit
coupé. Si le boîtier de coupure de courant se trouve au sous-sol, appeler
un électricien. Le non-respect de cet avertissement peut entraîner un choc
électrique morte.
www.waynepumps.com
WWB AUTO
Electric shock hazard! GFCI receptacles will provide
Risque de choc électrique! Le disjoncteur de fuite à
This pump must be plugged into a properly
Cette pompe doit être branchée dans une prise
Before each use inspect pump, power cord and plug
Avant chaque utilisation, vérifier que la pompe, le
Electrical wiring must be performed by a qualified
Le câblage électrique doit être réalisé par un
Do not abuse cord. Never use the cord to carry or
Prendre soin du cordon. Ne jamais utiliser le cordon
If there is water or moisture on the floor, do not walk
Si le sous-sol a de l'eau ou de l'humidité sur le
620013W-001 B 07/20

Advertisement

loading

Summary of Contents for Wayne WWB AUTO

  • Page 1 Si le boîtier de coupure de courant se trouve au sous-sol, appeler un électricien. Le non-respect de cet avertissement peut entraîner un choc électrique morte. © 2020, WAYNE/Scott Fetzer Company. www.waynepumps.com 620013W-001 B 07/20...
  • Page 2 Lors de l’entretien de cette pompe, seules des piéces de rechange originales de WAYNE doivent éure utilisées. Le non-respect de ces étapes Ce produit peutvous exposer à des produits chimiques, peut entrainer un risque d’inondation, de dégats matériels, de choc électrique mortel...
  • Page 3 Most electric product-related incidents are caused by feature can cause the pump to run dry and may damage the shaft seal and cause failure to observe basic safety rules or precautions. WAYNE Water Systems is NOT pump failure and void warranty.
  • Page 4 Single Phase, Auto ON/OFF HORSEPOWER 1/4 HP IMPELLER Thermoplastic CIRCUIT REQUREMENT 15 A (minimum) VOLUTE Thermoplastic PUMP DISCHARGE 3/4 in. Hose Threads PERFORMANCE Model Discharge Head 0 ft. 5 ft. 10ft. 15 ft. 20 ft. WWB AUTO Gal/hr 1900 1580 1250...
  • Page 5: Application And Operation

    OPEARATING INSTURCTIONS AND PARTS MANUAL STEP 1 - VERIFY PACKAGE CONTENTS STEP 5 - PLUG INTO GFCI OUTLET POWER CORD HANG LOOP STAINER BASE CARRYING DISCHARGE HANDLE STEP 2 - CONNECT GARDEN HOSE DESCRIPTION This portable, Auto On-Off Submersible Mult-Use Pump is designed for automatic removal of water.
  • Page 6: Maintenance

    OPEARATING INSTURCTIONS AND PARTS MANUAL MAINTENANCE TROUBLESHOOTING 1. To verify pump is operating correctly follow the steps below: NOTE: Minimal service is required for this pump. The motor housing of the pump is completely sealed and requires no internal a. Disconnect pump from power source. service or lubrication.
  • Page 7: Troubleshooting Chart

    LIMITED WARRANTY For three year for WWB Auto model from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser, any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.