OPEARATING INSTURCTIONS AND PARTS MANUAL
To reduce the risk of electric shock, install only on a
circuit protected by a Ground-Fault-Circuit-Interrupter (GFCI).
Pour réduire le risque de choc électrique, installez-le
uniquement sur un circuit protégé par un disjoncteur de fuite à la terre (GFCI).
The follwoing warning pertains only to the TSC130 pumps:
This pump is designed for indoor use only, unless
housed and protected from the elements.
Cette pompe est conçue pour une utilisation à l'intérieur
uniquement, sauf si elle est à l'abri et protégée contre les intempéries.
Most electric product-related incidents are caused by
failure to observe basic safety rules or precautions. WAYNE Water Systems is NOT
responsible for any bodily injury or property damage that may result from operation
outside of the normal operating conditions.
MISE EN GARDE
La plupart de incidents liès aux matèriels
èlectrique sont causès par le non-respect des règles de sècuritè our des
prècautions de base. WAYNE Water Systems N'EST PAS responsable des blessures
corporelles ou des dègats matèriels qui pourraient rèsulter d'une utilisation autre
que les conditions d'utilisation normales.
This pump has been evaluated for use with water only.
MISE EN GARDE
Cette pompe a été évaluée pour une utilisation
avec de l'eau uniquement.
This pump is not designed to handle salt water, brine,
laundry discharge, or any other application which may contain caustic chemicals,
highly chlorinated water, and/or foreign materials. This pump is not suitable for use
with aquatic life. Pump damage or failure could occur if used in these applications
and will void warranty.
When routing the electrical cord protect cord from
sharp objects, hot surfaces, oils, and chemicals. Do not kink cord, do not use with
damaged cord.
Do not allow pump to run dry. The shaft seal depends on
water for lubrication. Operating the pump without water will damage the shaft seal
and cause pump failure.
When the water level is approaching the minimum
pumping limit, the water removal rate may slow, and the pump may become noisy.
This is due to air being drawn into the pump in addition to water. During this time
the pump may still remove water. Once water has stopped coming out of the hose
unplug pump to avoid running dry.
Service work on this pump must be performed by a
qualified repair personnel. ONLY use identical WAYNE replacement parts.
Do not suspend pump by discharge pipe. Do not place
pump directly on clay, gravel, leaves or any loose or sandy surfaces. These surfaces
contain small stones, sand, or debris that may clog or damage the pump. This could
result in pump failure causing flooding and property damage.
The follwoing NOTE does not pertain to the TSC130 pumps:
NOTE: Acceptable for Indoor and Outdoor Use
Use an outdoor rated extension cord of the appropriate
gauge when necessary. Confirm the current (Amp) rating of the pump and the
length of the extension cord needed.
Current (Amps)
rating at 120V
up to 25
up to 4
18 gauge
up to 6
18 gauge
up to 10
16 gauge
AUTO UTILITY PUMPS ONLY
Do NOT alter the pump to override the automatic water
detector. The shaft seal depends on water for lubrication. Overriding this pump
feature can cause the pump to run dry and may damage the shaft seal and cause
pump failure and void warranty.
In small areas a check valve is required to prevent
backflow. Without a check valve the pump may cycle continuously and potentially
wear out the pump components.
Length of Cord (Feet)
up to 50
up to 100
18 gauge
16 gauge
16 gauge
14 gauge
14 gauge
12 gauge