Operating Instructions and Parts Manual
SPECIFICATIONS
POWER SUPPLY REQUIREMENTS
MOTOR
CIRCUIT REQUIREMENT
LIQUID TEMPERATURE RANGE
TANK SIZE
© 2018, WAYNE/Scott Fetzer Company.
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
120 V, 60 Hz
Synchronous Type
15 A (minimum)
40° F- 120° F
2 Quarts
PERFORMANCE
Model
Discharge Head
WCP85
Intended for Indoor Use Only
MOTOR HOUSING
MOTOR SHAFT
IMPELLER
VOLUTE
PUMP DISCHARGE
Max Flow
Gal/hr
85
www.waynepumps.com
Condensate Pump
CONSTRUCTION
Thermoplastic
Stainless Steel
Thermoplastic
Thermoplastic
3/8 in. Hose Barb
620010-001 B 08/18
WCP85

Advertisement

Table of Contents
loading

Summary of Contents for Wayne WCP85

  • Page 1 Thermoplastic LIQUID TEMPERATURE RANGE 40° F- 120° F PUMP DISCHARGE 3/8 in. Hose Barb TANK SIZE 2 Quarts PERFORMANCE Model Discharge Head Max Flow WCP85 Gal/hr Intended for Indoor Use Only © 2018, WAYNE/Scott Fetzer Company. www.waynepumps.com 620010-001 B 08/18...
  • Page 2: General Safety Information

    Operating Instructions and Parts Manual DESCRIPTION GENERAL SAFETY INFORMATION A condensate unit removes condensation from air conditioning CALIFORNIA PROPOSITION 65 and high efficiency furnaces. The compact design of the unit consists of a 3/8” ID discharge and 6 ft. long power cord. The unit also contains a safety switch to automatically shut off HVAC equipment in the event of a failure (Additional wiring required).
  • Page 3 Operating Instructions and Parts Manual WCP85 GENERAL SAFETY INFORMATION (CONT’D) PUMPS ARE NOT DESIGNED TO TRANSFER WATER INTENDED FOR DRINKING. Do not use the pump for moving water that will be used for portable/drinking water. Pump should only be used in NEVER REMOVE THE GROUND PRONG from the plug or bypass the applications for which it is designed.
  • Page 4: Installation

    Operating Instructions and Parts Manual A. Extend discharge pipe from barbed check valve to the highest GENERAL SAFETY INFORMATION (CONT’D) point possible. Refer to Figure 4. B. From this point, direct the discharge line to the location of the 1. Know the pump application, limitations, and po ten tial hazards. drainage source.
  • Page 5: Maintenance

    Operating Instructions and Parts Manual WCP85 INSTALLATION (CONT’D) 1. Release all pressure within the system before ser vic ing any component. 4. For optimum performance, drain and discharge lines should have a 2. Drain all liquids from the system before servicing.
  • Page 6 Operating Instructions and Parts Manual MAINTENANCE (CON’T) Typical Thermostat 4. Check hoses for weak and worn condition before seasonly, making Overflow Safety certain that all connections are secure. Switch 5. Periodically inspect the pump and system com po nents. Perform routine maintenance as required. CLEANING RESERVOIR AND IMPELLER 1.
  • Page 7: Troubleshooting Chart

    électricien agréé qualifié pour couper le service électrique avant le retrait de la pompe. Si la liste de vérification ci-dessus ne permet pas de résoudre le problème, contacter le service clientèle de WAYNE au 1-800-237-0987.
  • Page 8: Limited Warranty

    LIMITED WARRANTY For one year for WCP85 model from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser, any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.