Troubleshooting Chart - Wayne CDUCAP Series Operating Instructions And Parts Manual

Submersible sump pump
Hide thumbs Also See for CDUCAP Series:
Table of Contents

Advertisement

Available languages

Available languages

M a i n t e n a n c e
Always disconnect
the electrical supply
before attempting to install, service,
relocate or perform any maintenance.
If the power source is out of sight, lock
and tag in the open (off) position to
prevent unexpected power application.
Failure to do so could result in fatal
electrical shock. Only qualified
electricians should repair this unit.
Improper repair could result in fatal
electrical shock.
1 . Let the pump cool for a minimum of
two hours before servicing because
the pump contains hot oil under
pressure and the motor is hot.

Troubleshooting Chart

Symptom
Possible Cause(s)
Pump will not start or
1. Blown fuse
run
2. Low line voltage
3. Defective motor
4. Impeller
Pump starts and stops
1. Backflow of water from
too often
2. Incoming water is draining
Pump will not shut
1. Obstacle in piping
off or thermal
2. Low Line Voltage
protector turns off
3. Too many appliances on
4. Dirty water sensor
5. Incoming water is draining
Pump operates but
1. Plugged impeller
delivers little or no
2. Check valve installed
water
3. Pump airlocked
Gurgling sound from
1. Air injested into pump
pump at end of cycle
2. Time required for
2 . Disassembly of the motor prior to
expiration of warranty will void the
warranty. If repairs are required,
see troubleshooting chart.
3 . Inlet should be kept clean and free
of all foreign objects and inspect
annually. A clogged inlet will
damage pump.
4 . Pump should be checked monthly
for proper operation. Pump can be
checked for proper operation by
briefly removing pump power cord
from the back of the water sensor
plug and inserting directly into the
piping
on sensor face
circuit
on sensor face
backwards
pumping is less than 4
seconds
5 . Wipe water sensor surface regularly
cooling. This oil can be harmful to the
environment. Check the state
environmental laws before disposing
this oil.
Corrective Action
1. If blown, replace with proper sized fuse or reset breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. If impeller will not turn, remove housing and remove
blockage
1. Install or replace check valve
2. Position pump switch away from the inlet so switch is clear
from incoming water (see Figure 1)
1. Remove pump and clean pump and piping
2. If voltage is under 108 volts, check wiring size
3. Install pump on dedicated circuit. IMPORTANT: Do not use
extension cord to power pump.
4. Clean sensor face (see Figure 2)
5. Position pump switch away from the inlet so switch is clear
from incoming water (see Figure 1)
1. Clean out impeller
2. Reverse position of check valve
3. Drill 1/8" hole in discharge line between pump and check
valve
1. Wipe off surface of sensor (see Figure 2)
2. Additional run time will not damage pump
3
CDUCAP Series
grounded outlet. In this condition,
the pump will run continuously.
Once pump operation is verified,
replace pump power cord into the
back of the water sensor plug (see
Figure 2).
to prevent silt or other coatings
from building up on sensor face
(see Figure 2).
This pump contains
dielectric oil for
w w w .waynepumps. c o m