Wayne WSM3300 Operating Instructions & Parts Manual

Wayne WSM3300 Operating Instructions & Parts Manual

12 volt advanced notification system

Advertisement

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.
Failure to follow these instructions could result in property damage, bodily injury or death.
QUICK START INSTRUCTIONS
STEP 1 - VERIFY PACKAGE CONTENTS
Transformer (1)
Lid and Controller Assembly (1)
Battery box (1)
12 Volt DC back-up pump (1)
Switch with clamp (1)
Requires active telephone land line service
STEP 2 - DISCONNECT POWER
is out of sight, lock in the open
position and tag it to prevent
unexpected application of power.
Failure to do so COULD result in fatal
electric shock!
STEP 3 - INSTALL BACK-UP AND FLOAT SWITCH
STEP 4 - INSTALL BATTERY
© 2012, WAYNE/Scott Fetzer Company.
12 Volt Advanced
Notification System
OPERATING INSTRUCTIONS & PARTS MANUAL
Does not include:
12 Volt DC deep cycle
battery, phone jack,
phone line, pipe, and
necessary fittings.
If the power disconnect
Acceptable Batteries
WAYNE - WSB1275
WAYNE - WSB1240
or
12 Volt Deep Cycle Marine Battery
12 Volt SLA (Sealed Lead Acid)
12 Volt Deep Cycle Battery
12 Volt Wet Cell Battery
Size = min 40Ah
For parts, product & service information
STEP 5 - CONNECT LID TO BATTERY
Black
STEP 6 - CONNECT WIRES
Float Switch
Security
Phone
STEP 7 - POSITION BATTERY AND CONTROLLER
STEP 8 - CONTROLLER SETUP
Startup Display
Select Language
English
Español
Français
Select the starting language and follow the on-screen
instructions to set up the controller. Upon completion of
controller setup, restore AC power and test the main pump as
described in the operation section of the manual.
visit www.waynepumps.com
WSM3300
Wear safety glasses when
connecting the battery
Red
Transformer
DC Pump
12
9
3
6
Minimum charge time
before usage is 24 hours
Drain
Tile
Home Display
12.1 V
100%
Last Auto Test: --/--/--
System Armed & Ready
MENU MUTE RESET
354100-001 10/12

Advertisement

Table of Contents
loading

Summary of Contents for Wayne WSM3300

  • Page 1 12 Volt Wet Cell Battery controller setup, restore AC power and test the main pump as Size = min 40Ah described in the operation section of the manual. © 2012, WAYNE/Scott Fetzer Company. 354100-001 10/12 For parts, product & service information visit www.waynepumps.com...
  • Page 2: Specifications

    30 minutes. Seek NEVER allow children to use pump. medical attention. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2012, WAYNE/Scott Fetzer Company. www.waynepumps.com...
  • Page 3: Pump Installation

    Operating Instructions and Parts Manual WSM3300 TRANSFORMER FEATURES PUMP INSTALLATION 1. Turn power to main pump off. • When plugged into 120VAC, the transformer automatically provides power to the battery charging circuitry. 2. Pump must be installed using 1-1/4 in. or 1-1/2 in. rigid PVC piping.
  • Page 4 (sold separately, part switch, pump inlet, or main pump operation. The back-up #66002-WYN1 WAYNE adapter or equivalent) will be pump must not be allowed to run dry except during the 20 necessary. Smaller diameter piping will reduce pump second "auto-test.
  • Page 5: Control Box Installation

    Operating Instructions and Parts Manual WSM3300 CONTROL BOX INSTALLATION PHONE LINE INSTALLATION PHONE SYSTEM INFORMATION If battery cables are reversed, damage to the transformer, controller or battery COULD Sharing the phone jack: result, and warranty WILL be void. The 12 Volt Advanced Notification System and your existing Electric shock hazard.
  • Page 6 Operating Instructions and Parts Manual WSM3300 To make sure all timers and errors are cleared from the CRITICAL STEP: It is recommended that a person at the call-to system memory, press and hold the "RESET" button for location confirms receiving the test phone call. Validate all calls a minimum of 3-5 seconds.
  • Page 7: Operation

    Operating Instructions and Parts Manual WSM3300 the System tallies and remembers the number of rings. CANCELING AN ALARM CALL OUT SEQUENCE WITH AN ANSWERING MACHINE/VOICE MAIL DEVICE ON THE SAME 2. On your second call within “3” minutes, let the phone ring PHONE LINE until the System answers.
  • Page 8 Operating Instructions and Parts Manual WSM3300 2. The extension cord must have a ground wire and plug pin must be provided to the telephone company. and be connected to a properly functioning GFCI PLUG AND JACK USE receptacle. A plug and jack used to connect this equipment to the premises 3.
  • Page 9: Troubleshooting Chart

    Operating Instructions and Parts Manual WSM3300 Troubleshooting Chart Message Possible Cause(s) Corrective Action BACK-UP PUMP Pump Won't Run 1. Connections not secure 1. Check all connections 2. Low or defective battery 2. Check battery and replace if low or defective 3.
  • Page 10: Limited Warranty

    Limited Warranty For two years from the date of purchase, WAYNE Water Systems Division ("WAYNE Pumps") will repair or re place, at its option, for the original purchaser any part or parts of its Water Pumps (“Product”) found upon examination by WAYNE to be defective in materials or work man ship.
  • Page 11 Operating Instructions and Parts Manual WSM3300 Copy, cut out and save the following Quick Reference Cut-A-Way Card for your records. These are especially useful when you are not at home and need to contact the System to check the status, retrieve or cancel messages and alarms. It would also be useful to give this card to others who are on the call notification list for your System.
  • Page 12 Batterie à cellule humide de 12 volts pompe principale conformément à la description donnée dans la section Fonctionnement de ce manuel. Capacité = 40 Ah minimum © 2012, WAYNE/Scott Fetzer Company. Pour des renseignements sur les pièces, les produits et l’entretien, visiter www.waynepumps.com...

Table of Contents