Troubleshooting Chart - Wayne TSC Series Quick Start Manual

Dewatering pump
Table of Contents

Advertisement

Available languages

Available languages

WARRANTY & SYSTEM INSTALLATION GUIDE
If you have any questions regarding the service or
repair of this machine, call or write to:
WAYNE Pumps
Attn. Technical Services Department
101 Production Drive
Harrison, Ohio 45030
Tel: 1-800-237-0987

TROUBLESHOOTING CHART

Symptom
Possible Cause(s)
Pump will not
1. Blown fuse or breaker
start or run
2. Low line voltage
3. Worn motor
4. Impeller not rotating
5. Thermal Protector open
Pump starts but
1. Inlet screen clogged
delivers little or
2. Low line voltage
no flow
3. Restriction in discharge hose
4. Discharge lift too high
4
Corrective Action
1. If blown, replace with the proper sized fuse or reset the breaker.
2. If voltage is under 108 volts, check wiring size.
3. Replace pump.
4. If impeller will not turn, disconnect pump from power source,
remove volute cover and remove blockage.
5 a. Water temperature is too high, move to cooler water.
b. Inlet clogged, remove debris.
c. Motor seized, replace pump.
1. Clean debris from screen.
2. If voltage is under 108 volts, check wiring size.
3. Unwind garden hose, remove any kinks or restrictions in hose.
4. Water level to end of garden hose is 25 ft. or greater.
www.waynepumps.com