Troubleshooting Chart - Wayne TSC130 Operating Instructions And Parts Manual

Dewatering pump tsc
Hide thumbs Also See for TSC130:
Table of Contents

Advertisement

Operating Instructions and Parts Manual
MAINTENANCE INSTRUCTIONS (CONT'D)
1. Keep pump inlet clean and free of all foreign objects.
Inspect inlet at beginning of each use.
2. The motor housing is permanently sealed and requires
no service. Disassembly of the motor housing or
alteration of the power cord could result in fatal electrical
shock.
GARDEN HOSE
* a 3/4 in. diameter or greater
garden hose must be used

TROUBLESHOOTING CHART

Symptom
Possible Cause(s)
Pump will not
1. Blown fuse or breaker
start or run
2. Low supply voltage
3. Worn motor
4. Impeller not rotating
5. Thermal protector open
Pump starts but
1. Inlet screen clogged
delivers little or
2. Low suppl yvoltage
no flow
3. Restriction in discharge hose
4. Discharge lift too high
6
ELECTRIC CORD
CARRYING
HANDLE
Corrective Action
1. If blwon, replace with the proper sized fust or reset the breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. If impeller will not turn, disconnect pump from power source,
remove volute cover and remove blockage
5a. Water temperature is too high, move to cooler water
b. Inlet clogged, remove debris
c. Motor seized, replace pump
1. Clean debris from screen
2. If voltage is under 108 volts, check wiring size
3. Unwind garden hose, remove any kinks or restrictions in hose
4. Water level to end of garden hose is 25 ft. or greater
www.waynepumps.com