EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
b
a Solenoid coil
b Connector X5
5 Plug the gas boiler connector into connector X5 of the gas boiler PCB. Make
sure the solenoid coil is outside the gas boiler switch box.
6 Route the communication cable from the gas boiler to the indoor unit as in
figure below.
7 Open the switch box cover of the indoor unit.
8 Plug the indoor unit connector into X39A of the indoor unit PCB.
a