4 Connect the flexible tube (where applicable with the overflow pipe from the
pressure relief valve) to the drain via an open connection.
WARNING
ALWAYS fill the condensate trap with water and place it on the boiler before
powering up the boiler. See illustration below.
NOT placing or filling up the condensate trap may cause flue gases to come into
the installation room and can lead to dangerous situations!
In order to place the condensate trap, the front cover MUST be pulled forward or
removed entirely.
NOTICE
It is recommended that any external condensate pipe is insulated and increased to
Ø32 mm in order to prevent the condensate from freezing.
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump