8
|
Configuration
To copy the system settings from the first to the second user interface
Installer reference guide
122
Overview settings
01
00
00
01
20
04
05
08
09
0c
0d
Confirm
Adjust
5 Repeat previous steps if you have to modify other settings.
6 Push
to confirm the modification of the parameter.
7 At installer settings menu, press
Installer settings
The system will restart.
OK
Confirm
Result: The system will restart.
If a second user interface is connected, the installer must first proceed below
instructions for the proper configuration of the 2 user interfaces.
This procedure offers you also the possibility to copy the language set from one
user interface to the other one: e.g. from EKRUCBL2 to EKRUCBL1.
1 Turn on the unit.
Result: When turned on for the first time, both user interfaces display:
U5:Auto address
Push 4 sec. to continue
2 Push
for 4 seconds on the user interface on which you want to proceed to
the quick wizard.
Result: This user interface is now the main user interface.
INFORMATION
While using the quick wizard on the main user interface, the second user interface
displays Busy and you cannot interact with it.
3 On the display, check if there is a data difference between both user
interfaces.
Result: For proper operation of the system, the local data on both user
interfaces must be the same. If they contain different data, both user
interfaces will display:
Synchronization
Data difference detected.
Please select action:
Send data
Confirm
4 To make the data equal on both user interfaces, select the required action:
02
00
03
00
06
07
0a
0b
0e
0f
Scroll
to confirm the settings.
Cancel
Adjust
Tue
15:10
Adjust
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10