Daikin Altherma EVLQ05+08CA Installer's Reference Manual page 125

Hybrid heat pump
Hide thumbs Also See for Altherma EVLQ05+08CA:
Table of Contents

Advertisement

EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
#
Code
[A.2.1.7]
[C-07]
[A.2.1.B]
N/A
Description
Unit temperature control:
0 (LWT control): Unit operation is decided
based on the leaving water temperature
regardless the actual room temperature and/or
heating or cooling demand of the room.
1 (Ext
RT
control): Unit operation is
decided by the external thermostat or
equivalent (e.g. heat pump convector).
2 (RT
control)(default): Unit operation is
decided based on the ambient temperature of
the user interface.
Only if there are 2 user interfaces (1 installed in
the room, 1 installed at the indoor unit):
a
a: At unit
b: In room as room thermostat
User interface location:
At unit: this user interface is used to control
the
unit.
The
other
automatically set to In room.
In room (default): this user interface acts as
room thermostat. The other user interface is
automatically set to At unit
8
Configuration
|
b
user
interface
is
Installer reference guide
125

Hide quick links:

Advertisement

Table of Contents
loading