User reference guide
Daikin Altherma hybrid heat pump
EHYHBH05AA
EHYHBH08AA
User reference guide
EHYHBX08AA 
English
Daikin Altherma hybrid heat pump
EHYKOMB33AA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EHYHBH05AA and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin EHYHBH05AA

  • Page 1 User reference guide Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA User reference guide EHYHBX08AA  English Daikin Altherma hybrid heat pump EHYKOMB33AA...
  • Page 2: Table Of Contents

    To set the gas price ..............20 Indicates useful tips or additional information. To set the electricity price............20 To set the electricity price schedule timer ......... 21 DANGER: RISK OF EXPLOSION 6 Energy visualisation Indicates a situation that could result in explosion. To view the energy statistics ............. 21 7 Energy saving tips DANGER: RISK OF POISONING Indicates a situation that could result in poisoning. 8 Maintenance and service Overview: Maintenance and service.......... 21 WARNING: PROTECT AGAINST FROST To find the contact/helpdesk number ........21 Indicates  a  situation  that  could  result  in  equipment  or property damage. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 3: For The User

    Check  if  he  has  filled  in  the  installer settings tables. If not, request him to do so. ▪ Keep the documentation for future reference. Target audience End users Main zone. Example: Living room. Additional zone. Example: Bedroom. Documentation set Technical room. Example: Garage. This  document  is  part  of  a  documentation  set.  The  complete  set Outdoor unit heat pump consists of: Indoor unit heat pump Instant domestic hot water or domestic hot water (DHW) tank User interface at the indoor unit EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 4: Operation

    Overview of menu structure schedule in the menu structure). Installer settings table Overview of installer settings ▪ Enables you to activate or deactivate child lock if pressed for more than 5 seconds on a home page. ▪ Enables  you  to  activate  or  deactivate  a  function  lock  if pressed  for  more  than  5  seconds  in  the  main  menu  of  the menu structure. INFORMATION If you press   or   while changing settings, the changes will NOT be applied. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 5: Status Icons

    Select schedules Information A malfunction occured. Press   to display more Select Scroll information about the malfunction. Weather­dependent mode is active. To navigate in the menu structure User permission level = Installer. Use  ,  ,  ,  ,   and  Defrost/oil return mode is active. Hot start mode is active. Emergency operation is active. INFORMATION When the gas boiler is in maintenance mode, a gas boiler test  run  is  being  performed  or  changes  to  settings  are being saved, the user interface displays Busy. If this is the case, the user interface is temporarily disabled so as not to allow interference with the actions the system is performing at that moment. EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 6: Turning On/Off Controls

    ▪ Additional leaving water temperature home page (LWT add) Unit is heating up your space at this 2 Press  moment. To turn ON or OFF the domestic hot water control Operation mode = cooling. 1 Go to the DHW tank temperature home page (Tank). Unit is NOT cooling down your space. However, the DHW tank can be 2 Press  heating up. To turn ON or OFF the instant domestic hot water control Operation mode = cooling. 1 Go to the instant DHW temperature home page (DHW). Unit is cooling down your space at this 2 Press  moment. Space heating/cooling control 4.4.1 About space heating/cooling control Controlling  space  heating/cooling  typically  consists  of  the  following stages: Setting the space operation mode Controlling the temperature User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 7: Controlling The Temperature

    1 Press    multiple  times  to  switch  between  home  pages,  and following: check  if  the  additional  leaving  water  temperature  home  page (LWT add) is available: You can… Location Read out the actual and desired room Room temperature If … Then you have… temperature. home page Available A main zone and an additional Temporarily overrule the room temperature zone schedule. NOT available Only a main zone EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 8 Define preset values that are used by the room temperature schedule, and when you ▪ "4.7 Preset values and schedules" on page 16 change the mode from scheduled to preset External room thermostat control value. External  room  thermostat  control  means  that  you  control  the See also: following: ▪ "Using the room temperature home page" on page 8 ▪ Room temperature on the external thermostat control ▪ "To set the overrule period" on page 9 ▪ Leaving water temperature on the user interface (Daikin) ▪ "4.7 Preset values and schedules" on page 16 Leaving water temperature of the main zone To control the leaving water temperature, you can do the following: To control the leaving water temperature of the main zone, you can do the following: You can… Location Read out the desired leaving water Leaving water You can… Location temperature. temperature home Read out the desired leaving water...
  • Page 9 ▪ Tonight  you  have  a  party  and  you  want  to  use  the  preset  value schedule. (Comfort) until 02:00. Desired temperature = custom temperature = 19°C. Then you can do the following: At the next scheduled action 1 Set the overrule period (Temperature lock) to 6 hours. (17:00), the schedule will be used again. 2 At 20:00, go to the room temperature home page (Room). 3 Press   to select  . Result:  The  preset  value  (Comfort)  will  be  used  until  02:00. After that, the schedule will be used again. EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 10: Domestic Hot Water Control

    About domestic hot water control additional) Your  system  layout  may  or  may  not  contain  a  domestic  hot  water Go to the leaving water temperature home page (LWT main or LWT tank.  When  no  tank  is  installed,  the  boiler  provides  domestic  hot add). water instantly. When, on the contrary, a tank is installed, domestic hot water control is different depending on the DHW tank mode set by the installer: ▪ Reheat mode ▪ Scheduled mode ▪ Scheduled + reheat mode User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 11: Instant Dhw (No Tank Installed)

    As  long  as  the  DHW  tank  temperature Scheduled mode stays above 40°C, hot water is available. Scheduled + reheat mode   ▪ At 14:00 the DHW tank is programmed to heat up the water to a preset  value  (example:  Storage  eco  =  50°C).  Hot  water  is available again. ▪ During  the  afternoon  and  evening,  you  consume  hot  water  again and the DHW tank temperature decreases again. ▪ At 00:00 the next day, the cycle repeats. EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 12 Storage comfort Advantages: 00:00 Desired temperature ▪ You will have sufficient hot water (= comfortable). ▪ You do NOT have to change the schedule (= easy). Depending on an installer setting, you have to define how much hot water you want differently: ▪ You  do  NOT  have  to  activate  the  DHW  tank  booster  mode  (=  energy saving). If you see… Then you have to define… To which temperature the 60°C DHW tank has to heat up. For how many people you need hot water. The software then automatically calculates the corresponding DHW tank temperature based on installer settings. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 13: Advanced Usage

    To check if quiet mode is active ▪ Domestic  hot  water  operation  can 1 Press   to go to one of the home pages. be turned ON or OFF. If you decide 2 If   is displayed, quiet mode is active. to  keep  it  turned  ON,  domestic  hot water control will be according to the desired  DHW  tank  temperature  of the selected day. EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 14 4 Activate the holiday mode. Usage example: You come home during your holiday Possible holiday mode settings (when you stay at home) If you are in the following situation: Setting Description ▪ You configured and activated the holiday mode (Away). From and Until First and last day of your holiday. ▪ During your holiday, you come home for a few hours and want to Use day Day schedule used during your holiday. use your normal schedule. schedule  Example: Saturday To configure the holiday (when you go away) Then you can do the following: 1 Go to [2.2]:   > Holiday > Holiday mode. 1 Deactivate the holiday mode. 2 Select Away. 2 When you go away again, activate the holiday mode again. 3 Configure the holiday mode settings (when you go away). 4 Activate the holiday mode. Advantage: You do NOT have to change your schedule or holiday configuration. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 15: Reading Out Information

    [6.1] Sensor information  Room, tank or DHW, outside, and leaving water temperature. User profile Example (If applicable) Basic  15:20 [6.2] Energy metering  Produced energy, consumed Room electricity, and consumed gas. [6.5] Actuators  Status/mode of each actuator. Example: Domestic hot water 20.0°C pump ON/OFF. [6.6] Operation modes  Current operation mode. Actual temperature Example: Defrost/oil return Detailed  mode. 15:20 20.0°C Room [6.7] Running hours  Running hours of the system. [6.8] Version  Version information about the Actual temperature system. Scheduled 17:30 EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 16: Locking And Unlocking Buttons And Functions

    Using and programming schedules To activate or deactivate child lock About schedules 1 Press   to go to one of the home pages. Depending  on  your  system  layout  and  installer  configuration, 2 Press   for more than 5 seconds. schedules (predefined and/or user­defined) for multiple controls may To activate or deactivate a function lock be available. 1 Press   to go to the menu structure. You can: 2 Press   for more than 5 seconds. ▪ Select which schedules you currently want to use. 3 Select a function and press  ▪ Program your own schedules if the predefined schedules are not 4 Select Lock or Unlock, and press  satisfactory. The actions you can program are control specific. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 17: Schedules: Example

    3 Change  the  name  and  press  .  (Only  applicable  for  room Set heating schedule temperature schedules). Example: MyWeekSchedule Comfort Delete line Clear day schedule Copy day Save schedule -- : -- Select Scroll You can: ▪ Delete lines from the schedule ▪ Clear a day schedule ▪ Copy from one day to others EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 18: Predefined Schedules: Room Temperature + Leaving Water Temperature (Main)

     : Additional zone = On : Additional zone = OFF Predefined 1 Mon ­ Fri 07:00 09:00 17:00 23:00 Sat ­ Sun 08:00 23:00 Predefined 2 Mon ­ Fri 07:00 09:00 12:00 14:00 17:00 23:00 Sat ­ Sun 08:00 23:00 Predefined 3 Mon ­ Sun 08:00 23:00 INFORMATION The  predefined  schedules  are  applicable  for  both  heating and cooling operation. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 19: Menu Structure: Overview

    LWT additional Tank temp. Quiet mode DHW pump Elec price [7.4] Preset values Room temperature LWT main Tank temperature Quiet level Elec price Fuel price [7.6] Unit of measurement Decimal point Temperature Pressure Produced energy Flow Consumed gas EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 20: Installer Settings: Tables To Be Filled In By Installer

    1 (Yes) significant values). Leaving water temperature: Emitter type [A.3.1.1.7] Emitter type 0 (Quick) To set the electricity price Savings mode [A.6.7] 1 Go to [7.4.5]:   > User settings > Preset values > Elec price. Savings mode 2 Use   and   to set the correct prices for High, Medium and (Economical) Low, according to your electricity tariff. Electricity price [7.4.5] 3 Press   to confirm. Elec price 20/kWh (High) INFORMATION 20/kWh (Medium) Price  value  ranging  from  0.00~990  valuta/kWh  (with  2 15/kWh (Low) significant values). User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 21: To Set The Electricity Price Schedule Timer

    Example:  When  you  have  a  party,  or  when  you are leaving for a couple of hours. ▪ For  longer  periods:  You  can  use  the  holiday  mode.  Example: When  you  stay  at  home  during  your  holiday,  or  when  you  go away during your holiday. EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 22: Troubleshooting

    If the problems recurs daily, do one of the following: ▪ Increase  the  DHW  tank temperature preset value. ▪ Adjust  the  DHW  tank temperature  schedule. Example:  Program  additionally  heat  up  DHW  tank  to  a  preset  value (Storage  eco  =  lower  tank temperature) during the day. User reference guide EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA Daikin Altherma hybrid heat pump 4P355632­1 – 2013.05...
  • Page 23 Equipment  made  or  approved  by  Daikin  that  can  be combined  with  the  product  according  to  the  instructions  in the accompanying documentation. Field supply Equipment  not  made  by  Daikin  that  can  be  combined  with the  product  according  to  the  instructions  in  the accompanying documentation. EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA User reference guide...
  • Page 24 4P355632­1  2013.05...