Set weather-dependent heating:
T t
[1-02]
[1-03]
[1-00]
T
: Target leaving water temperature (main)
t
T
: Outdoor temperature
a
Code
<< continuation
[1‑00]: Low outdoor ambient temperature. –
40°C~+5°C (default: –10°C)
[1‑01]: High outdoor ambient temperature.
10°C~25°C (default: 15°C)
[1‑02]: Desired leaving water temperature
when the outdoor temperature equals or
drops below the low ambient temperature.
[9‑01]°C~[9‑00]°C (default: 60°C).
Note: This value should be higher than [1-03]
as for low outdoor temperatures warmer
water is required.
[1‑03]: Desired leaving water temperature
when the outdoor temperature equals or
rises above the high ambient temperature.
[9‑01]°C~min(45, [9‑00])°C (default: 35°C).
Note: This value should be lower than [1-02]
as for high outdoor temperatures less warm
water is required.
Code
Only for EHYHBX08. Set weather-
dependent cooling:
T t
[1-08]
[1-09]
[1-06]
T
: Target leaving water temperature (main)
t
T
: Outdoor temperature
a
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Description
[1-01]
T a
continued >>
Description
Description
[1-07]
T a
continued >>