Daikin Altherma EVLQ05+08CA Installer's Reference Manual page 158

Hybrid heat pump
Hide thumbs Also See for Altherma EVLQ05+08CA:
Table of Contents

Advertisement

8
|
Configuration
Heat source settings
Installer reference guide
158
NOTICE
Disinfection mode. Even if you turn OFF domestic hot water operation via the
DHW tank temperature home page (Tank), disinfection mode will remain active.
INFORMATION
Disinfection function is restarted in case the domestic hot water temperature drops
5°C below the disinfection target temperature within the duration time.
INFORMATION
An AH error occurs if you do the following during disinfection:
Set the user permission level to Installer.
Go to the DHW tank temperature home page (Tank).
Press to interrupt the disinfection.
Auto emergency
When the heat pump fails to operate, the gas boiler can serve as an emergency
back-up heater and either automatically or non-automatically take over the entire
heat load.
When auto emergency is set to Automatic and a heat pump failure occurs, the
boiler will automatically take over the heat load.
When auto emergency is set to Manual and a heat pump failure occurs, the
domestic hot water and space heating operations will stop and need to be
recovered manually. The user interface will then ask the user to confirm whether
the boiler can take over the entire heat load or not.
When the heat pump fails,
unattended for longer periods, we recommend to set [A.6.C] Emergency to
Automatic.
#
Code
[A.6.C]
N/A
INFORMATION
The auto emergency setting can be set in the menu structure of the user interface
only.
INFORMATION
If a heat pump failure occurs and [A.6.C] is set to Manual, the room frost protection
function, the underfloor heating screed dryout function, and the water pipe
antifreeze function will remain active even if the user does NOT confirm emergency
operation.
Equilibrium temperature
Based on the ambient temperature, energy prices and the required leaving water
temperature, the user interface is able to calculate which heat source can deliver
the required heating capacity most efficiently. However, to maximise the energy
output of the heat pump, it is possible to prevent the gas boiler from operating
will appear on the user interface. If the house is
Description
Emergency:
0: Manual (default)
1: Automatic
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump