Daikin EHYKOMB33AA Installation And Operation Manual

Daikin EHYKOMB33AA Installation And Operation Manual

Hide thumbs Also See for EHYKOMB33AA:
Table of Contents

Advertisement

Quick Links

Installation and operation manual
Daikin Altherma hybrid heat pump – gas boiler
module
Installation and operation manual
English
Daikin Altherma hybrid heat pump – gas boiler module
EHYKOMB33AA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EHYKOMB33AA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin EHYKOMB33AA

  • Page 1 Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module Installation and operation manual English Daikin Altherma hybrid heat pump – gas boiler module EHYKOMB33AA...
  • Page 2 2P369568-3H...
  • Page 3: Table Of Contents

    Building Regulations and should be provided to the customer for Finishing the gas boiler installation ........... 24 future reference. 7.8.1 To close the gas boiler..........24 EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 4: About The Documentation

    Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). General safety precautions About the documentation ▪...
  • Page 5: For The Installer

    (on top of the instructions described in the Daikin documentation). EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 6: Water

    III condition, MUST be installed in the fixed wiring. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 7: Gas

    Flue systems must NOT be modified or installed in any way other than as described in the fitting instructions. Any misuses or unauthorized modifications to the appliance, flue or associated EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 8: About The Box

    4.1.2 To remove the accessories from the gas boiler 1 Remove the accessories. Mounting strip Condensate trap Installation and operation manual Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 9: About The Units And Options

    Combining units and options EKFGP4664 Elbow PP/GLV 60/100 30° INFORMATION Certain options might not be available in your country. EKFGP4661 Elbow PP/GLV 60/100 45° EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 10 Weather slate steep Pb/GLV 80/125 18°-22° EKFGT6301 Weather slate steep Pb/GLV 80/125 23°-27° EKFGP6325 Connector flex-flex PP 100 EKFGP7909 Weather slate steep PF 80/125 25°-45° RAL 9011 Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 11: Preparation

    It is recommended to first install: ▪ the water piping, ▪ the refrigerant piping, ▪ the electrical connection to the heat pump module. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 12: Installation

    Removing the top plate of the indoor unit makes it easier to install the gas boiler. 7.2.1 To install the gas boiler 1 Lift the unit from the package. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 13: To Install The Condensate Trap

    A suitable permanent connection to the pipe from the pressure relief valve) to the drain via an open foul waste pipe should be used. connection. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 14: External Connections

    (<0.3 l) has a temperature higher Ø22 mm than 60°C. Condensate discharge from boiler Soil and vent stack Sink or basin with integrated overflow Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 15: Connecting The Electrical Wiring

    Outlet space heating Inlet space heating 1 Open the gas boiler. 2 Open the switch box cover of the gas boiler. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 16: Connecting The Gas Piping

    2 Install a gas mesh filter in the gas connection if the gas may be contaminated. 3 Connect the gas boiler to the gas supply. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 17: Connecting The Boiler To The Flue Gas System

    To change the gas boiler to 80/125 concentric connection The concentric connection can be changed from Ø60/100 to Ø80/125 by an adapter set. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 18: Calculate The Total Piping Length

    Please note that NOT all flue gas configurations as described below are allowed in all countries. Please follow the local and national regulations. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 19 L1 (m) L1 (m) L1 (m) L1 (m) 80/125 80/125 80/125 60/100 L1 (m) L1 (m) L1 (m) L2 (m) L1 (m) L2 (m) EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 20: Applicable Materials

    Gas exhaust/air intake parts can be bought from a third L1+L2 (m) L1 (m) L1 (m) L1+L2 (m) party. All parts purchased from an external supplier MUST comply with EN14471. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 21: Flue Pipe Position

    From an opening in a car port (e.g. door, window) into a dwelling Vertically from a terminal on the same 1500 wall EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 22: Fitting A Vertical Flue System

    ▪ Make sure that all joints and seams are gastight and watertight. ▪ Make sure that the flue system has a uniform gradient back to the boiler. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 23: About Securing The Flue System

    ▪ Every system MUST contain at least 1 bracket. ▪ Position the first clamp at a maximum of 500  mm from the gasboiler. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 24: Finishing The Gas Boiler Installation

    Finishing the gas boiler installation 7.8.1 To close the gas boiler 1 Hook the top of the front panel into the top of the gas boiler. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 25: To Install The Cover Plate

    INFORMATION Resetting is only possible when an error occurs. Prerequisite: Flashing LED above the button and an error code on the main display. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 26 99. It is however possible to set this parameter to 100% (default setting). We strongly recommend not modifying this setting. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 27 Maximum fan rpm 45~50 Use this parameter to set the maximum fan rpm. It is recommended not to modify this setting. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 28 The gas valve is sealed. In Belgium, any modifications to the gas valve MUST be performed certified representative manufacturer. For more information, contact your dealer. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 29 CO setting of the boiler is correct. If NOT, adjust the CO setting according to the instructions in the chapter below. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 30: Operation

    Operation modes 7 Put the front panel back in its place. The following codes on the service display indicate the following operating modes. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 31: 10 Commissioning

    [ 4   32]. Static pressure MUST be 20  mbar (+ or – operation mode. During the space heating operation, the fan speed 1  mbar). If the working pressure is <19  mbar, the gas boiler EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 32: To Perform A Test Run On The Gas Boiler

    Before performing any maintenance or service work, touch a metal part of the unit in order to eliminate static electricity and to protect the PCB. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 33 11 Push the backside of the condensate drain pan downwards from the connection to the heat exchanger and remove it. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 34: To Clean The Inside Of The Gas Boiler

    18 Close the display cover. base tray. 19 Check the heating and hot water supply. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 35: Troubleshooting

    ▪ Replace the gas valve. ▪ Clean the appliance and flue ▪ Re-adjust the gas valve, see system. "To check CO₂ setting" [ 4  29]. EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 36: Symptom: Space Heating Does Not Reach The Temperature

    For detailed troubleshooting of each error, see the service manual. Dealer Sales distributor for the product. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 37 Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with product according instructions accompanying documentation.
  • Page 38: 14 Technical Data

    14 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 14.1 Components 14.1.1...
  • Page 39: Wiring Diagram

    Heating power space heating (80/60) 8.2~26.6 kW Gas consumption (G25, Natural gas LL/ 0.89~3.92 m³/h Efficiency space heating (net calorific value 80/60) Gas consumption (G31, Liquefied 0.30~1.29 m Propane gas) EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 40 — Any modifications to the gas valve MUST be performed by a certified representative of the manufacturer. For more information, contact your dealer. Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 41 G20 (20 mbar) — G31 (37 mbar, 2H3P 50 mbar) Romania G20 (20 mbar) — G31 (30 mbar) 2H3P Turkey G20 (20 mbar) — — Ukraine G20 (20 mbar) — — EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 42 Local Authority Building Control (LABC) either directly or through a Competent Persons Scheme. A Building Regulations Compliance will then be issued to the customer. www.centralheating.co.uk www.centralheating.co.uk Installation and operation manual EHYKOMB33A Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 43 Local Authority Building Control (LABC) either directly or through a Competent Persons Scheme. A Building Regulations Compliance will then be issued to the customer. © Heating and Hotwater Industry Council (HHIC) www.centralheating.co.uk EHYKOMB33A Installation and operation manual Daikin Altherma hybrid heat pump – gas boiler module 4P353067-1K – 2020.10...
  • Page 44 88454708 4P353067-1K 2020.10 Verantwortung für Energie und Umwelt...