EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
Item
Description
Optional equipment
7
3‑way valve
8
Domestic hot water tank
thermistor
9
Power supply for drain pan
heater
10
Room thermostat/heat
pump convector
11
Outdoor ambient
temperature sensor
12
Indoor ambient
temperature sensor
Field supplied components
13
Shut-off valve
14
Electricity meter
15
Domestic hot water pump
16
Alarm output
17
Changeover to external heat
source control
18
Space cool/heat operation
control
19
Power consumption digital
inputs
20
Gas meter
21
Safety thermostat
(a) Refer to name plate on outdoor unit.
(b) Minimum cable section 0.75 mm².
(c) Use the cable supplied with the boiler.
(d) The thermistor and connection wire (12 m) are delivered with the domestic hot
water tank.
(e) Cable section 0.75 mm² till 1.25 mm²; maximum length: 50 m. Voltage-free contact
shall ensure the minimum applicable load of 15 V DC, 10 mA.
(f) Cable section 0.75 mm² till 1.25 mm²; maximum length: 500 m. Applicable for both
single user interface and dual user interface connection.
(g) Cable section 1.5 mm
NOTICE
More technical specifications of the different connections are indicated on the inside
of the indoor unit.
Wires
3
2
2
3 or 4
2
2
2
2
2
2
2
2
2 (per input signal)
2
2
2
; maximum length: 50 m.
6
Preparation
|
Maximum
running current
(b)
100 mA
(d)
(b)
(b)
100 mA
(b)
(b)
(b)
100 mA
(b)
(b)
(b)
(b)
(b)
(b)
(b)
(e)
Installer reference guide