Daikin EHYHBH05AA Installation Manual

Daikin EHYHBH05AA Installation Manual

Altherma hybrid heat pump – heat pump module
Hide thumbs Also See for EHYHBH05AA:
Table of Contents

Advertisement

Installation manual

Daikin Altherma hybrid heat pump – heat pump
module
EHYHBH05AA
Installation manual
EHYHBH08AA
English
Daikin Altherma hybrid heat pump – heat pump module
EHYHBX08AA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EHYHBH05AA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin EHYHBH05AA

  • Page 1: Installation Manual

    Installation manual Daikin Altherma hybrid heat pump – heat pump module EHYHBH05AA Installation manual EHYHBH08AA English Daikin Altherma hybrid heat pump – heat pump module EHYHBX08AA...
  • Page 2 3P353176-1D...
  • Page 3: Table Of Contents

    ▪ A subset of the latest technical data is available on the regional 4.6.1 To close the indoor unit..........12 Daikin website (publicly accessible). 5 Configuration ▪ The full set of latest technical data is available on the Daikin extranet (authentication required). Indoor unit ................. 12 5.1.1 Overview: Configuration..........12 5.1.2...
  • Page 4: About The Box

    In case of plastic pipes, make sure they are fully oxygen printed. diffusion tight according to DIN  4726. The diffusion of oxygen into the piping can lead to excessive corrosion. Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 5: To Check The Water Volume And Flow Rate

    1 Remove the side panel at the right side of the indoor unit. The boiler side panel is fixed at the bottom with 1 screw. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 6: Mounting The Indoor Unit

    4.2.1 To install the indoor unit 1 Put the installation pattern (see box) on the wall and follow the steps as shown below. Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 7: Connecting The Refrigerant Piping

    5 Fill the circuit with water until the boiler display indicates a pressure of ±2 bar (with a minimum of 0.5 bar). 6 Purge air from the water circuit as much as possible. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 8: To Fill The Domestic Hot Water Tank

    ▪ Shut-off valve (field supply) ▪ Domestic hot water pump (field supply) ▪ Interconnection cable between indoor unit and gas boiler (see boiler manual for connection instructions) Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 9: To Connect The Main Power Supply Of The Indoor Unit

    ▪ If you use 2 user interfaces, you can install 1 user interface at the indoor unit (for control close to the indoor unit) + 1 user interface in the room (used as room thermostat). EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 10: To Connect The Shut-Off Valve

    4C From the top 4D From the top centre 1× 1× 2 Fix the cable with cable ties to the cable tie mountings. Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 11: To Connect The Gas Meter

    1 Connect the power consumption digital inputs cable to the appropriate terminals as shown in the illustration below. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 12: To Connect The Safety Thermostat (Normal Closed Contact)

    EITHER preferential kWh rate power supply OR a safety menu structure. thermostat. Accessing settings via the code in the Code overview settings. See also: ▪ "To access the installer settings" on page 13 Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 13 The user permission level will stay in Adv. end user until set set from one user interface to the other one: e.g. from EKRUCBL2 to otherwise. EKRUCBL1. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 14 OFF and "busy" will be displayed for several seconds. "To copy the system settings from the first to the second user interface" on page 13. Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 15: Basic Configuration

    ▪ 4 (Type 5). EKHWP. turned ON. ▪ 6 (Type 7) Third-party tank. Range: 0~6. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 16 Compares the primary energy use of the heat pump with that of the boiler. Open output Closed output Range: 0~6, step: 0.1 (default: 2.5) Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 17 Set the settings carefully; they have significant influence on heat pump as well as boiler operation. Too high leaving water temperature can result in constant boiler operation. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 18 This setting can compensate for a slow or a quick heating/cooling system by adjusting the unit capacity during the heat up/cool down cycle. Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 19: Menu Structure: Overview Installer Settings

    DI Test run UFH screed dryout Air purge Actuator test run INFORMATION Depending on the selected installer settings, settings will be visible/invisible. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 20: Commissioning

    The stop valves (gas and liquid) on the outdoor unit are fully open. The air purge valve is open (at least 2 turns). Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 21: To Perform An Air Purge

    > Installer settings > Commissioning > result in cracking of the screed. Actuator test run. 4 Select an actuator and press . Example: Pump. EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 22: Hand-Over To The User

    Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required).
  • Page 23: Wiring Diagram: Indoor Unit

    Translation S6S~S9S Digital power limitation inputs Position in switch box Position in switch box SS1 (A4P) Selector switch TR1, TR2 Power supply transformer EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 24 Only for wired thermostat DHW pump Domestic hot water pump Only for wireless thermostat Only for wireless thermostat Electrical and gas meter Electrical and gas meter Installation manual EHYHBH05AAV3* + EHYHBH/X08AAV3* Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 25 4 core Heat pump part Gas boiler part 3 core unit power supply: 230 V + earth X2: 2-4-earth Gas boiler 3D082242-1A EHYHBH05AAV3* + EHYHBH/X08AAV3* Installation manual Daikin Altherma hybrid heat pump – heat pump module 4P349587-1F – 2016.10...
  • Page 28 4P349587-1F 2016.10...

This manual is also suitable for:

Ehyhbx08aaEhyhbh08aa

Table of Contents