15
|
Technical data

15.6 ESP curve: Indoor unit

5 kW
A (kPa)
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
8 kW
A (kPa)
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
Installer reference guide
232
Note: A flow error will occur when the minimum water flow rate is not reached.
C
2
4
6 7 8
10
C
2
4
6
8
10
A External static pressure
B Water flow rate
C Minimum water flow rate
Boiler bypassed
Boiler not bypassed
Note: Selecting a flow outside the area of operation can cause damage or
malfunction of the unit. Water quality MUST be according to EN directive
EC98/83EC.
12
14
16
18
12
14
16
18
20
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
B (l/min)
20
22
24
B (l/min)
22
24
26
4D082239-1C
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10