Daikin Altherma EVLQ05+08CA Installer's Reference Manual page 243

Hybrid heat pump
Hide thumbs Also See for Altherma EVLQ05+08CA:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
A.2.1.8
[7-02]
Number of LWT zones
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.A
[E-04]
Power saving possible
A.2.1.B
User interface location
└─ Options
A.2.2.1
[E-05]
DHW operation
A.2.2.2
[E-06]
DHW tank
A.2.2.3
[E-07]
DHW tank type
A.2.2.4
[C-05]
Contact type main
A.2.2.5
[C-06]
Contact type add.
A.2.2.6.2
[D-07]
Digital I/O PCB
A.2.2.6.3
[C-09]
Digital I/O PCB
A.2.2.7
[D-04]
Demand PCB
A.2.2.8
[D-08]
External kWh meter 1
A.2.2.A
[D-02]
DHW pump
A.2.2.B
[C-08]
External sensor
A.2.2.C
[D-0A]
External gas meter
└─ Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.2.3
[9-03]
Temperature range
A.3.1.1.2.4
[9-02]
Temperature range
A.3.1.1.5
[8-05]
Modulated LWT
A.3.1.1.6.1
[F-0B]
Shut-off valve
A.3.1.1.6.2
[F-0C]
Shut-off valve
A.3.1.1.7
[9-0B]
Emitter type
└────────────────── Additional
A.3.1.2.1
LWT setpoint mode
A.3.1.2.2.1
[9-05]
Temperature range
A.3.1.2.2.2
[9-06]
Temperature range
A.3.1.2.2.3
[9-07]
Temperature range
A.3.1.2.2.4
[9-08]
Temperature range
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
A.3.2.1.2
[3-06]
Room temp. range
A.3.2.1.3
[3-09]
Room temp. range
A.3.2.1.4
[3-08]
Room temp. range
A.3.2.2
[2-0A]
Room temp. offset
A.3.2.3
[2-09]
Ext. room sensor offset
A.3.2.4
Room temp. step
└─ Operation range
A.3.3.1
[4-02]
Space heating OFF temp
A.3.3.2
[F-01]
Space cooling On temp
└─ Domestic hot water (DHW)
└─ Type
*HYHBH/X*AA/FV3
Solar kit
Alarm output
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Thermo On/OFF
Cooling
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (cooling)
Maximum temp (cooling)
Range, step
Default value
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0: Continuous
1: Sample
2: Request
R/O
1: Yes
R/W
0: At unit
1: In room
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0~6
4: Type 5
6: Type 7
R/W
1: Thermo ON/OFF
2: C/H request
R/W
1: Thermo ON/OFF
2: C/H request
R/W
0: No
1: Yes
R/W
0: Normally open
1: Normally closed
R/W
0: No
1: Pwr consmp ctrl
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
R/W
0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~80°C, step: 1°C
80°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Quick
1: Slow
R/W
0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~80°C, step: 1°C
80°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
12~18°C, step: A.3.2.4
12°C
R/W
18~30°C, step: A.3.2.4
30°C
R/W
15~25°C, step: A.3.2.4
15°C
R/W
25~35°C, step: A.3.2.4
35°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: 1°C
1: 0,5°C
R/W
14~35°C, step: 1°C
25°C
R/W
10~35°C, step: 1°C
20°C
3/8
Installer setting at variance with
default value
Date
Value
4P353731-1H - 2021.02