Script and configuration

7.1

Overview

The script stored in the UNIGATE
via the serial interface (application) in the configuration mode.
7.2

The configuration mode

If the pin „ConfigMode" pulled to GND during the PowerUp or Reset, then the UNIGATE
starts in the configuration mode. In this mode it is possible to communicate with the IC without
processing the regular software. In this mode it is possible to change the UNIGATE
of the standard software or to write a new script in the UNIGATE
figuration mode by issuing a status message (it may take up to 1 minute), which might look as
follows:
IC-PN-SC V0.4 [30](c)dA Script(16k)="Leer" Author="Deutschmann Automation GmbH"
Version="1.0" Date=21.08.2001 SN=47110001 IP=172.16.48.62 MAC=00-14-11-15-19-81
7.3

Update the script

The preferred option is to insert the UNIGATE
(Developer Board UNIGATE
„Write Script" under „File" or with the software ScriptProgramTool).
You can also automatically replace the script in your application from your host (see flowchart).
27.11.20
Instruction manual UNIGATE
®
IC, as well as the configuration, can be replaced or updated
®
IC into the base board from Deutschmann
®
IC-AB) and use the Deutschmann tools (software WINGATE with
®
IC - PROFINET 1Port V. 3.4
Script and configuration
®
IC's settings
®
IC. It shows its start in the con-
®
IC
27