Type 38 spring set brake
Table of Contents

Advertisement

Optional Components
CAUTION
5.
Verify the air gap X is set to the adjusted dimension as shown on the table above.
2021 KEB America, Inc.
©
Loss of Braking Torque!
 For the safe operation of the brake, the proper adjustment of
dimension m is mandatory!
 Operation of the brake with dimension m smaller than the listed
dimension will result in loss of braking torque.
 Do not operate the brake with wear beyond Xn as listed above!
i
 The adjustment dimension m on the previous table applies to the
listed rated torque, nominal air gap, and rated voltage for the
brake. If you are operating the brake with different values than
those listed in this manual, contact KEB America, Inc. for
adjusted m dimensions.
Refer to section Adjusting the Air Gap.