Dc Side Switching With External Mov; Figure 12 Rectifier Wiring: External Mov - KEB COMBISTOP Instruction Manual

Type 38 spring set brake
Table of Contents

Advertisement

Installation
5.4.1.3

DC Side Switching with External MOV

When the brake is de-energized via the DC side switching, some of the energy stored in
the magnetic coil of the brake is absorbed by the varistors in the rectifier. High cycle rates
together with large brake coils can result in an overload of the rectifier. In this case an
external MOV should be used connected in parallel to the brake as shown below. The
voltage rating of the MOV is dependent on the supply voltage of the rectifier.
The following MOVs are recommended for use with the listed supply voltage.
Supply Voltage
120V, 208V, 230V, 240V
400V, 480V
2021 KEB America, Inc.
©

Figure 12 Rectifier Wiring: External MOV

KEB Material Number
0090045-2753
0090045-6255
Rectifier Model
0691010-001U
Varistor Voltage
275VACrms
625VACrms
31

Advertisement

Table of Contents
loading

Table of Contents