Download Print this page

Appendix A Specifications And Reference Data - Emerson AMS User Manual

Wireless vibration monitor
Hide thumbs Also See for AMS:

Advertisement

User Guide
MHM-97927-PBF
A
Specifications and reference data
A.1
Functional specifications
Input
Output
Humidity limits
Transmit rate
Measurement
MHM-97927-PBF, DRAFT
Three internal MEMS accelometers oriented in the X-Y-Z direction. The Z
accelometer has the greatest bandwidth and is considered the primary sensor.
The device also has a temperature sensor designed to read the temperature
near the mounting point.
Wireless-enabled, linear with temperature or input.
0–95% relative humidity
User-selectable, 60 seconds to 1 hour.
Measurement Parameters
The device is capable of measuring and reporting machine health
measurement parameters and generating alerts based on overall vibration in
each axis as well as peak impact measurements in the primary axis and
temperature readings.
Measurement precision
Measurement precision refers to the variability of the same measurement in a
fixed operating environment under steady-state conditions. For vibration, this
value is obtained with statistical measurements with 1 g-peak (9.81 m/s
input excitation at a frequency of 100 Hz. For temperature, this value is
obtained with statistical measurements at room temperature.
Vibration: 0.2 dB
Temperature: +/- 2°C
Amplitude Range
Up to 80 g's in the primary axis and at least 10 g's minimum in the secondary
axes (20 g's range preferred)
Measurement Accuracy
Linear to +/- 3dB out to 5 KHz minimum in the primary axis (10 KHz are
strongly preferred) and linear to +/-3dB out to 1.5 KHz minimum (5 KHz range
preferred) in the secondary axes
Dynamic signal range
Target: 85dB
Specifications and reference data
July 2020
2
)
63

Hide quick links:

Advertisement

loading