Download Print this page

Overall Velocity, Peakvue, And Temperature - Emerson AMS User Manual

Wireless vibration monitor
Hide thumbs Also See for AMS:

Advertisement

User Guide
MHM-97927-PBF
5
Overall Velocity, PeakVue, and
temperature
5.1
Overall Velocity
The Overall Velocity measurement provides a summation of the low-frequency vibration
energy, which indicates fault conditions such as imbalance, misalignment, looseness, and
late-stage bearing problems.
The AMS Wireless Vibration Monitor uses (lower-frequency) Overall Velocity in
conjunction with (higher-frequency) PeakVue to provide a holistic solution across all
frequencies while optimizing the usage of the limited power and bandwidth available in a
wireless device. The majority of developing fault conditions manifest in one or both of
these key parameters.
The difference between the standard vibration waveform and the associated PeakVue
waveform is shown in
shaft rotation, expressed in units of RMS velocity per the ISO 10816 standard. PeakVue, on
the other hand, filters out the rotational energy to focus on impacting. Impacting is
expressed in units of Peak acceleration. This indicates key mechanical problems such as
rolling element bearing faults, gear defects, and under-lubrication.
Figure 5-1: Velocity waveform
MHM-97927-PBF, DRAFT

Overall Velocity, PeakVue, and temperature

Figure 5-1
and
Figure
5-2. Overall Vibration indicates energy from
July 2020
53

Hide quick links:

Advertisement

loading