CHAPTER 3 Settings and Measurement
Illumination /
ultraviolet sensor
(GS-LXUV)
CO2 sensor
(GS-CO2)
Adapter for AC
current sensor
(GS-DPA-AC)
EU
(Scaling settings)
Misc.
3-22
Setting
Range
[Illuminance] / [Accumulated
illuminance]
[Ultraviolet] / [Accumulated
ultraviolet]
Filter
Range
Filter
Range
AC clamp mode
[Current]
[Power] / [Accumulated
power]
Filter
Function
Meas. Value Upper limit
Lower limit
EU output
Upper limit
Lower limit
Dec pt
Select
Unit
Arbitrary unit
Annotation text string
Inter-
Function
CH Op
Operation
Settings
Scaling
Upper/Lower limit
Dec pt
Select
Unit
Arbitrary unit
Span
Upper limit
settings
Lower limit
Waveform color setting
Line Thickness Setting
Trace setting
Perform Auto Zero ADJ.
* When using the GS-3AT, the auto
balance is performed.
Reset Auto Zero ADJ.
* When using the GS-3AT, the auto zero
is released.
Accumulated reference temperature
Accumulated polarity
CO2 calibration
Voltage
Power factor
Selections available
2000, 20000lx, 200klx
30mW/cm
fixed
2
None
5000ppm fixed
None
AC 1P2W, AC 1P3W, AC 3P3W
50, 100, 200A
(20, 50, 100kW) Change in synchronization with the current range.
None
Off, On
* When measuring the humidity, "On" is fixed.
Set numeric value
Set numeric value
Set numeric value
Set numeric value
EU output upper limit x 0.01, x 1, x 10, x 100, x 1000
Cur, Length, Area, Volume, Velocity, Accel, Freq, Mass, Energy,
Pressure, Flow , Temp, Strain, Brightness, Concentration
(The selections vary depending on the unit selected in the above.)
Enter text (Max. 8 characters)
Enter text (Max. 31 characters)
Off, On
CH-X (+, -, x, /) CH-Y
/1000000, /1000, ×1, ×1000, ×1000000
Set numeric value
×1, ×10, ×100, ×1000, ×10000
Cur, Length, Area, Volume, Velocity, Accel, Freq, Mass, Energy,
Pressure, Flow , Temp, Strain, Brightness, Concentration
(The selections vary depending on the unit selected in the above.)
Enter text
Set numeric value
Set numeric value
0 to 31 for each of red, green, blue (RGB)
1 to 8 dots
Off, On
Press right key to execute.
* This function is not available for the temperature setting.
Press right key to execute.
* This function is not available for the temperature setting.
-20 to +85°C
* Available for GS-TH sensor only.
High/Low
* Available for GS-TH sensoronly.
Off, On
* Available for GS-CO2 sensor only.
90 to 264
* Available for GS-DPA-AC adapter only.
0.30 to 1.00
* Available for GS-DPA-AC adapter only.