Docking Funnel
!
8.2 Safety Measures Prior and After Maintenance
Prior to performing maintenance work (safety inspection, cleaning, removing parts, installing
parts, etc.), following safety measures must be taken:
Ensure that the AMR has come to a complete stop, by pressing the E-Stop button on the
l
Operator Panel
Power OFF the AMR by pressing the OFF button on the Operator Panel
l
Once maintenance work has completed, and the AMR is ready for use, take following actions:
Power ON the AMR by pressing the ON button on the Operator Panel
l
Release the E-Stop
l
8.3 Lifting the Platform Safely
If, for any reason, you need to lift the platform by hand, take care to lift from safe lifting points.
!
Front Lifting Points
Lift on each side of the laser, under the upper side of the laser slot. Do not lift at the center -
there is no supporting frame. Do not lift anywhere else! Refer to the following illustration:
11970-000 Rev M
WARNING: MAGNETIC FIELD - MEDICAL IMPLANT RISK
Magnetic fields can be hazardous to medical implant wearers. Medical
Implant wearers should stay at least 30 cm away from the underside of the
platform, which is exposed during certain maintenance procedures when the
platform is tipped on its side.
CAUTION: PROPERTY DAMAGE RISK
Lifting the platform from the wrong points can damage the platform.
LD-60/90 Platform User's Manual
Chapter 8: Maintenance
127