Quick BTAC Series User Manual page 13

Electric thrusters
Hide thumbs Also See for BTAC Series:
Table of Contents

Advertisement

5 - Installation
BTAC Series
EN
5.5 - Oil tank positioning
• Fit the oil tank (1) above the waterline by at least 20% of the distance (d) from the waterline to the centre of the tunnel. This is
for ensuring enough overpressure of oil in the gearhouse.
• Fill the oil tank with gear oil type GL-5
1
> 0,2 x d
Waterline
d
Tunnel center line
POSITION THE PIPE CORRECTLY, IN ORDER TO PREVENT "SIPHON" EFFECT.
THE TANK MUST ALWAYS END UP IN VERTICAL POSITION.
AIR
OIL
INSTALLATION AND USE MANUAL BTAC SERIES - REV000A