Quick BTAC Series User Manual
Quick BTAC Series User Manual

Quick BTAC Series User Manual

Electric thrusters
Hide thumbs Also See for BTAC Series:

Advertisement

Quick Links

BTAC
DOUBLE PROPELLER
BTAC250200 • BTAC300300 • BTAC300350 • BTAC386420 • BTAC386460 • BTAC 5131000
ELECTRIC THRUSTERS
USER MANUAL
series
REV 000A
IT
pag. 3

Advertisement

Table of Contents
loading

Summary of Contents for Quick BTAC Series

  • Page 1 BTAC series REV 000A DOUBLE PROPELLER BTAC250200 • BTAC300300 • BTAC300350 • BTAC386420 • BTAC386460 • BTAC 5131000 ELECTRIC THRUSTERS USER MANUAL pag. 3...
  • Page 3 7.0 - Warnings Pag. 16 8 - Usage Pag. 17 9 - Maintenance Pag. 17 10 - Disposal of the product Pag. 17 11 - Spare parts Pag. 18 12 - Dimensions Pag. 21 INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 4: Information About The Product

    ® QUICK® RESERVES THE RIGHT TO INTRODUCE CHANGES TO THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE. IN CASE OF DISCREPANCIES OR ERRORS BETWEEN THE TRANSLATED TEXT AND THE ORIGINAL ITALIAN TEXT, PLEASE REFER TO THE ITALIAN TEXT 1.0 - Technical data...
  • Page 5: Supplied Parts

    We recommend using an appropriate personal protective equipment. Quick thrusters are not suitable for installation in potentially explosive environments and/or atmospheres. ® Assembly and subsequent checks or repairs must only be carried out by qualified personnel. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 6 BTAC Series THE PRODUCT MUST BE DISCONNECTED FROM THE HYDRAULIC SYSTEM BEFORE INSTALLING OR PROVIDING MAINTENANCE. Quick® takes no responsibility regarding the inadequate connection of the users to the hydraulic system and to the safety of itself. 3.2 - Installation requirements It is strongly recommended to entrust a professional with the preparation and positioning of the tunnel in the hull.
  • Page 7: Installation

    • For a correct use of the thruster we suggest a maximum length of 3-4 times the tunnel diameter and a minimum length of 1,5 times the tunnel diameter. To limit efficiency loss it is acceptable a length that is six times the tunnel diameter. MAXIMUM 6 TIMES TUNNEL Ø MINIMUM 1,5 TIMES TUNNEL Ø INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 8 • If the tunnel is near the waterline, it is advisable to fit a grating at the end of the tube. The grating must have vertical and as large as possible meshes to avoid contrasting the propeller thrust. The vertical meshes prevent the entry of most of the floating objects. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 9 • Take care that there are no resin residues in the contact area between flange and tube; this could cause misalignment. Any resin residues and any other hindrance to correct contact must be removed by sandpaper. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 10 • Insert the elastic joint in the terminal part of the small key into its seat. gearleg shaft. • Grease the terminal part of the gearleg shaft. • Insert the motor onto the elastic joint. Secure with four screws and four washers. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 11 • Fig.F Proceed with fitting the gearleg. For further protection against the entry of water, apply silicone for nautical use around the point of contact between flange and tube. Fasten everything to the flange using the special screws. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 12 Rilsan Tube and oil tank BTAC 513 • After fixing the flange, turn the fitting clockwise and • Insert the Rilsan pipe into the fitting with the special align it with the flange opening. expansion tank. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 13 • Fill the oil tank with gear oil type GL-5 > 0,2 x d Waterline Tunnel center line POSITION THE PIPE CORRECTLY, IN ORDER TO PREVENT “SIPHON” EFFECT. THE TANK MUST ALWAYS END UP IN VERTICAL POSITION. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 14 2 - Lubricate the end of the motor shaft and mount 3 - Mount the motor on the gearleg and fix it to the support. the upper half-joint. 4 - Tighten the coupling screw, hold down towards the gearleg. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 15 The anodes F must be locked with the screws G soaked with building adhesive (such as Loctite). ONLY Ø513 WARNING: Once the assembly is over, make sure that the propellers are exactly positioned at the centre of the tunnel. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 16: Connection Diagram

    75 kW 400 V 75 kW 90 kW *this data refer to S3 operating mode (periodic intermittent duty) - for any modification please contact Quick 7 - Warnings BTAC series 7.0 - Warnings WARNING: This thruster is not designed for a continuous use. It is equipped with protections which limit its operation at a maximum time span, as reported on the controls’...
  • Page 17: Maintenance

    Local legislation may include the application of serious fines in the event of improper disposal of this product. INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 18: Spare Parts

    5 OSP KIT PROPELLER D250 LH FVSGEL250L00A00 5 OSP KIT PROPELLER D300 LH FVSGEL300L00A00 6 OSP KIT ANODES PROPELLER BT 250 ALL FVSGANBTQ25AA00 6 OSP KIT ANODES FOR PROPELLER BT 300 ALL FVSGANBTQ30AA00 INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 19 OSP KIT ANODES PROPELLER BT 386 ALL FVSGANBTQ38AA00 OSP KIT EVEN TENSION DEVICE D109 BT 386 FVSGGPVP1090A00 OSP GEARLEG KIT BT 386 R2 FVSGGBBT3862A00 OSP KIT GASKET BT 386 R2 FVSGGRBT3862A00 OSP KIT PROPELLER D386L P740 COMP FVSGEL386L50A00 INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 20 OSP KIT FLEX COUPLING D120 BT 513 FVSGGPVP1200A00 OSP KIT GEARBOX BT513 FVSGGBBT5130A00 OSP KIT ANODES PROPELLERS BT 513 ALL FVSGEL513R01A00 OSP KIT PROPELLER D513R P600 COMP FVSGEL513R40A00 OSP KIT PROPELLER D513L P600 COMP FVSGEL513L40A00 INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 21 12 - Dimensions BTAC Series BTAC 250 15 kW 373 (14 BTAC 300 BTAC 300 15 kW 22 kW 434 (17 434 (17 INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 22 12 - Dimensions BTAC Series BTAC 386 BTAC 386 37kW 30kW Ø 566 (22 19/64) Ø 566 (22 INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 23 12 - Dimensions BTAC Series BTAC 513 75kW 720 mm (28" 11/32 in) INSTALLATION AND USE MANUAL BTAC SERIES - REV000A...
  • Page 24 BTAC series REV 000A INSTALLATION AND USE MANUAL Product code and serial number QUICK S.p.A. - Via Piangipane, 120/A - 48124 Piangipane (RAVENNA) - ITALY ® Tel. +39.0544.415061 - Fax +39.0544.415047 - www.quickitaly.com - quick@quickitaly.com...