4.13

Operation DRO5

Display: three position display, one speed display
Counting resolution setting function
Counting direction setting
Linear error compensation
Metric / inches change-over
LCD display status setting
Speed mode setting
Basic value setting

4.13.1 Keyboard (eight keys)

Function selection key, enter key.
Moving key
Increase or decrease key of the digits

4.13.2 Operations

Axial function
In the normal display state, press (X,Y, Z) key to make the corresponding axial value flash.
After flash several times, this axis will be cleared.
If the value of the indicator is blinking, press the corresponding axis button again to cancel the
operation.
If the displayed value is in flashing state, press again the function button "PROG" in order to
change the fundamental value of the axis.
Modification of the basic value of X, Y, Z
After entering this option, the basic value is highlighted, and the digital bit is located in the flash-
ing state. The ↑ ↓ keys are used for changing the digital bit, the ← → keys are used for select-
ing the digital bit. After completing the changes, press the "PROG" key to exit the option.

4.13.3 Menu

The operating modes of the menus are nearly same. The ↑ ↓ key move the cursor to the speci-
fied options, the "PROG" key is used to select. For optional items, using ↑ ↓ key to select, and
using the "PROG" key to exit after completing. For modifying items,
using ↑ ↓ key to modify the digital bit, using ← → key to select the digital bit, using "PROG" key
to exit after completing. Pressing the "PROG" key in multilevel menus enters the next level
menu.
GB
DRO 5
34
The selection keys of axes
Translation of original instructions
Version 1.0.4 - 2020-12-15