Mitsubishi NZ2GFCF-D62PD2 User Manual page 265

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

(9) Remote registers (RWw10 to RWw13, RWw28 to RWw2B)
Address
(RWw)
Item
CH1 CH2
10
28
Ring counter lower
11
29
limit value
12
2A
Ring counter upper
13
2B
limit value
(10)Remote registers (RWw14 to RWw15, RWw2C to RWw2D)
Address
(RWw)
Item
CH1 CH2
14
2C
Preset value setting
15
2D
• When the ring counter function is selected and CH Counter format (address:
0124
, 0144
) is set to Ring Counter (1), set the count range.
H
H
• Set the ring counter upper limit value as well.
• The following shows the setting range.
-2147483648 to 2147483647
• The reflection timing of the setting value
1)
When Initial data processing request flag (RX8) turns off
2)
When Initial data setting request flag (RY9) is turned off then on (only while
Initial data processing request flag (RX8) is off)
3)
When CH Count enable command (RY24, RY3C) is turned off then on
• When the ring counter function is selected and CH Counter format (address:
0124
, 0144
) is set to Ring Counter (1), set the count range.
H
H
• Set the ring counter lower limit value as well.
• The following shows the setting range.
-2147483648 to 2147483647
• The reflection timing of the setting value
1)
When Initial data processing request flag (RX8) turns off
2)
When Initial data setting request flag (RY9) is turned off then on (only while
Initial data processing request flag (RX8) is off)
3)
When CH Count enable command (RY24, RY3C) is turned off then on
• Set a count value to be replaced with the preset value for either of the
preset/replace (at coincidence output) function, the preset/replace function,
the count disable/preset/replace function, or the latch counter/preset/replace
function.
• The following shows the setting range.
-2147483648 to 2147483647
• The reflection timing of the setting value
1)
When Initial data processing request flag (RX8) turns off
2)
When Initial data setting request flag (RY9) is turned off then on (only while
Initial data processing request flag (RX8) is off)
3)
While Initial data processing request flag (RX8) and Initial data setting
request flag (RY9) are off
Description
Description
APPENDICES
Default
A
0
0
Default
0
263

Advertisement

Table of Contents
loading

Table of Contents