(5) Pulse measurement function
Pulses can be measured with 100ns measurement resolution. The pulse width (ON width/OFF width) can be
precisely measured. Various pulse measurement applications such as the workpiece length measurement or the
transport/processing speed management of various types of transport equipment and processing equipment are
available.
Example: Filling process (container type identification control)
Pulse
(6) Coincidence output function
This function compares a preset value with the input count value. If they match, the function outputs a signal and
thus the fixed-feed control is possible.
Control example: Drilling process (fixed-feed control)
driller
Counter input
Encoder
CHAPTER 1 HIGH-SPEED COUNTER MODULE
Light sensor
Coincidence output
(inverter stop)
Inverter