Mitsubishi NZ2GFCF-D62PD2 User Manual page 247

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Remote input
Signal name
(RX) No.
RX2A
CH1
Latch count
value update
flag reset
completed
(Latch counter
input terminal)
RX42
CH2
RX2B
CH1
Latch count
value update
flag (Latch
counter input
terminal)
RX43
CH2
RX2C
CH1
Update flag
reset completed
(Measured
frequency
value)
RX44
CH2
Update flag
reset completed
(Measured
rotation speed
value)
• This signal turns on when resetting CH Latch count value update flag (Latch counter input
terminal) (RX2B, RX43) by CH Latch count value update flag reset command (Latch
counter input terminal) (RY2A, RY42) is completed.
• This signal turns off when CH Latch count value update flag reset command (Latch
counter input terminal) (RY2A, RY42) is turned off.
Controlled by the high-speed counter module
Controlled by the program
CH
Latch count value update flag reset command
(Latch counter input terminal)
CH
Latch count value update flag
(Latch counter input terminal)
CH
Latch count value update flag reset completed
(Latch counter input terminal)
• This signal turns on when CH Latch count value (Latch counter input terminal) (RWr18 to
RWr19, RWr30 to RWr31) is updated.
(
Page 127, Section 8.5)
• CH Latch count value (Latch counter input terminal) (RWr18 to RWr19, RWr30 to RWr31)
is updated without resetting this flag.
• This signal turns off when CH Latch count value update flag reset command (Latch
counter input terminal) (RY2A, RY42) is turned on.
*1
• Up to ΔT
delay occurs until this signal turns on after CH Latch count value (Latch
1
counter input terminal) (RWr18 to RWr19, RWr30 to RWr31) is updated.
(For the overview of the operation, refer to the description of CH Latch count value update
flag reset completed (Latch counter input terminal) (RX2A, RX42).)
For ΔT
*1
, refer to Page 283, Appendix 4.
1
• This signal turns on when resetting CH Update flag (Measured frequency value) (RX2D,
RX45) by CH Update flag reset command (Measured frequency value) (RY2C, RY44) is
completed.
• This signal turns off when CH Update flag reset command (Measured frequency value)
(RY2C, RY44) is turned off.
Controlled by the high-speed counter module
Controlled by the program
CH
Update flag reset command
(Measured frequency value)
CH
(Measured frequency value)
CH
Update flag reset completed
(Measured frequency value)
• This signal turns on when resetting CH Update flag (Measured rotation speed value)
(RX2D, RX45) by CH Update flag reset command (Measured rotation speed value)
(RY2C, RY44) is completed.
• This signal turns off when CH Update flag reset command (Measured rotation speed
value) (RY2C, RY44) is turned off.
(The operation is the same as that of CH Update flag reset completed (Measured
frequency value) (RX2C, RX44) except the signal name.)
Description
ON
(RY2A, RY42)
OFF
ON
(RX2B, RX43)
OFF
ON
(RX2A, RX42)
OFF
ON
OFF
(RY2C, RY44)
ON
Update flag
OFF
(RX2D, RX45)
ON
OFF
(RX2C, RX44)
APPENDICES
A
245