Mitsubishi NZ2GFCF-D62PD2 User Manual page 185

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

CH1 External preset/replace (Z Phase) request detection setting
CH1 Counter function selection
CH1 Function input logic setting
CH1 Latch counter input logic setting
CH1 Z phase input response time setting
CH1 Function input response time setting
CH1 Latch counter input response time setting
CH1 Pulse measurement setting (Function input terminal)
CH1 Pulse measurement setting (Latch counter input terminal)
Set the initial values for the parameters in CH2 and the extension output module.
(b) Extended parameter (remote buffer memory) setting
Set the extended parameter (remote buffer memory) only when using the cam switch function.
Set it to operate Cam switch output 1 for CH1 Present value as shown below.
Cam switch function, step type (Output 1)
Cam switch function, number of steps (Output 1)
Cam switch function, step No.1 setting (Output 1)
Cam switch function, step No.2 setting (Output 1)
Cam switch function, step No.3 setting (Output 1)
Cam switch function, step No.4 setting (Output 1)
Cam switch function, step No.5 setting (Output 1)
Cam switch function, step No.6 setting (Output 1)
● The setting value in the item related to the cam switch function is enabled when CH Cam switch execute command
(RY26, RY3E) is turned off then on. However, the extended parameter is set before turning on then off Initial data setting
request flag (RY9) to save the extended parameter to the nonvolatile memory in this program.
● The extended parameters can be read/written only by the REMFR/REMTO instruction unlike the parameters.
Setting item
Present
to
100
to
250
value
ON
Output 1
OFF
Setting item
0: ON at detection (Initial value)
Set a value according to the counter function to be used.
0: Positive Logic (Initial value)
0: Positive Logic (Initial value)
Set any response time.
Set any response time.
Set any response time.
0: Pulse ON Width (Initial value)
1: Pulse OFF Width
to
400
to
550
to
700
to
850
to
0: Starts with output status being OFF
6
100
250
400
550
700
850
CHAPTER 9 PROGRAMMING
Setting value
Setting details
183
9

Advertisement

Table of Contents