Troubleshooting - Kessel Pumpfix F Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Clean the components
Clean all the dismantled components in the water bath
(using a brush if necessary).
7.4
Grease the components with seals
Grease the following components with seals:
Slide-in flap housing
Lockable cover
Seal on the swivel connection
Grease the backwater flap and motor-driven lever where the two components touch each other
7.5
Assemble the components
Mount the pump first, as the pump tries to start up when power is supplied to the control unit (SDS).
Reinstall the components in reverse order, at the same time perform a functional test (see "Commissioning", page 28).
Make sure that the motor-driven flap is open (indicated on the display) and that no faults are indicated on the control unit.
Document the maintenance in the control unit, set the next maintenance date.
8

Troubleshooting

Troubleshooting is described in the control unit's operating and maintenance instructions.
010-843
Installation and operating instructions
31 / 96

Advertisement

Table of Contents
loading

This manual is also suitable for:

24125801028009824150s2415024200 ... Show all

Table of Contents