Ip Parameters - Siemens SIRIUS 3RW5 Equipment Manual

Ethernet/ip communication module
Hide thumbs Also See for SIRIUS 3RW5:
Table of Contents

Advertisement

Configuring
6.2 Configuring the 3RW5 soft starter
3. Address the adapter (3RW5 Soft Starter) in the configuration software of the controller
with the aid of the previously set IP parameters.
Note the information in chapter IP parameters (Page 66).
4. Load the configuration into the scanner (if required).
Result
The 3RW5 soft starter is configured in the EtherNet/IP system, and can communicate with
other EtherNet/IP devices via the 3RW5 EtherNet/IP communication module.
6.2.1.3

IP parameters

All EtherNet/IP devices use the TCP/IP protocol and therefore need an IP address to operate
on EtherNet/IP.
IP parameters
● IP address
● Subnet mask
● Router address
Temporary IP parameters
If parameter "IP address setting" (Page 67) is set to "Via BOOTP/DHCP server", the
3RW5 EtherNet/IP communication module restarts without a valid IP address and resends
DHCP messages.
Note the settings in the configuration software of the controller.
Note
Set static IP parameters
Static IP parameters that were previously set are overwritten and deleted by temporary IP
parameters.
66
SIRIUS 3RW5 EtherNet/IP communication module
Equipment Manual, 03/2020, A5E45131885002A/RS-AB/002