B. Electric Wiring
a. Cautions on electric wire clamping method
1. There should be no contact or possible contact with surroundings of wire.
There should be no contact of wire at a place where no protective material is provided.
2. Do not clamp electric wire together with fuel hose.
3. Connect couplers, terminals etc. securely so that they should not be removed when they are pulled by
rather strong force.
4. Clamp wire harness surely to clamping position. (Clamp the portion of white tape)
1) Clamp the wire harness at the positions which are indicated by taping on the
wire harness.
2) Clamp the wire harness securely so that it should not be displaced nor move.
* Wire harness should not be extruded from the slit of corrugated tube.
* Clamp the cord over the wound corrugated tube.
Red line on black ground
Bold line on red ground
Taping
Clamp Them.
Starter switch
White line on black ground
White line on red ground
horn
V-S-5
RA118-5331
Wire harness
relay
Cord band
timer relay
fuse
5
light
starter
SW
5
Wire harness
regulater
Battery
body
Battery
ground