b. Pump
Pump (Main) assembly drawing
(1)
(2)Route of delivery hose
Assembly procedure
1) Pump assembly (gear) mounting torque:
39.2 ~ 45.1 N·m(4.0 ~4.6 kgf·m)
* Apply screw lock agent.
2) Mount the adaptor of No.1 pump side 18 deg.-
20 deg. upwards and the adaptor of No. 2
pump side 31 deg.- 33 deg. upwards.
Adaptor tightening torque:
37.2 ~ 42.1 N·m(3.8 ~ 4.3 kgf·m)
3) Pipe joint mounting torque:
58.8 ~ 63.7 N·m(6.0 ~ 6.5 kgf·m)
4) Plug (Seal) tightening torque:
15 ~ 16.5 N·m(1.5 ~ 1.7 kgf·m)
Pipe joint (Inlet, 2)
Pump, assembly (Gear)
Plug (Seal)
P2 elbow joint (G3-G2)
P1 elbow joint (G3-G2)
Provide a clearance of more than 5 mm at
the wire harness clamp of the bracket (step).
Provide a clearance of more than 5 mm
between the bolt and the support (step).
Provide a clearance of more than 5 mm at
the support (step).