Traveling System - Kubota K008-3 Workshop Manual

Hide thumbs Also See for K008-3:
Table of Contents

Advertisement

e. Traveling system
Whole type
Maker
Gradability
Max. tractive force
Traveling block performance
Traveling speed
1-speed
2-speed
Crawler rotating speed
Straight
traveling
perfor-
mance
Standard value
At lock
of drain volume
At rotation
1. Measuring procedure
Temperature of hydraulic oil: 50± 5 °C
(1) Measuring procedure of traveling block performance
1)
Carry out traveling operation on 20 deg. slop more than thrice.
2)
Put marks to the under carriage and the crawler, and measure the displacement generated for 10 min.
3)
Measure the displacement more than twice, and indicate the largest value.
(2) Crawler rotating speed
1)
Lift up the machine, put a mark to the crawler, perform traveling about a half turn and conduct measurement
more than twice.
Note:
The K008-3's 2-speed type is available only on the KTC, KCL and KTA versions.
Unit
K008-3
TRBV31C1101-A
Eaton Fluid Power
Ltd.
Deg. (Angle)
30
kN(kgf)
5.0(505)
> =
mm/10min
300
in./10min
> =
11.8
km/h
2.0/4.0
-
sec/10min
19 ±
sec/10min
10 ±
sec./turn
5.0 ± /2.6 ±
mm/10min
> =
1000
> =
in./10min
39.4
L/min
-
gal/min
L/min
-
gal/min
Bring the front attachment into traveling posture.
IV-S-16
U10-3
Remarks
TRBV31C1101-A
Eaton Fluid Power
Ltd.
30
8.5(870)
1F
> =
Traveling
300
20 deg., for 10 min.,
engine stopped, no-
load
2.0/4.0
1F/2F G
-
1F/2F Iron
19 ±
G
10 ±
G
5.5 ± /2.7 ±
1F/2F
> =
Traveling
1000
10
m
engine
speed
1F/2F
-
1F/2F
-
posture,
posture,
interval,
at
max.