(a) If the number of ports with
loads is n (n≤4), the first n-1 ports
must load the same number of
cabinets, which must also be an
integral multiple of the number
of cabinet rows or columns and
be greater than or equal to the
number of cabinets for the nth
ports.
(b) In the case of special-shaped cabinets, different cabinet sizes and special-shaped
screen, the NovaLCT-Mars software is required to be connected to configure the screen.
(c) During Data Flow setting, you can rotate the button to see the effects of different data
flow on the screen in real time. If you are satisfied with the effect of current data flow,
you must press the button to save the setting. You can press the ESC to exit from the
current operation.
(d) During Data Flow setting, you must ensure that the data flow of each port is
downward in the same direction.
(e) During Data Flow setting, you must ensure that Port 1 is the start position of the
whole data flow connection.
The VX4S-N can load 2.3 million (2048x1152@60Hz) pixels in maximum. The width of
lateral load can reach to 3840 pixels in maximum (3840x600@60Hz); the longitudinal
load can reach to 1920 pixels in maximum (1200x1920@60Hz).

Step 3: Brightness

Return to the main menu interface. Press the Knob to select the corresponding value of
Brightness. You can rotate the Knob to adjust the value at this time.
Brightness
Screen Settings
Input Settings
Output Settings

Step 4: Output Settings

Output settings are divided into three cases:
First one: disable Scaling, i.e., the sizes of output image and input image are the same,
and original scale output is used. If the input resolution is smaller than the LED display in
one direction, LED display may not become bright in this direction; if the input resolution
is greater than the LED display in one direction, the input contents may not be displayed
completely in this direction. This option is applicable to the application scenarios requiring
V X 4S - N U s e r M a nu a l
Example:
For example, if port 1, port 2, port 3 have loads,
port 1 and port 2 must have the same number of
cabinets, which must also be an integral multiple of
the number of cabinet rows or columns. Therefore,
you only need to set port 1 cabinet Qty according
to the actual situation when setting the screen. The
number of receiving cards port 3 loads must be
smaller than or equal to port 1.
25%
-7-
Brightness
Screen Settings
Input Settings
Output Settings
25%