Locating Smartids - Viavi OneExpert DSL User Manual

Hide thumbs Also See for OneExpert DSL:
Table of Contents

Advertisement

Chapter 11 In Home Testing
About SmartID tests
The purpose of SmartID tests are to test and map cables/wires, verify that the HPNA links
and devices are installed and fully provisioned, and to verify that the entire HPNA network is
operating correctly
From the Main menu, select In Home.

Locating SmartIDs

The purpose of this test is to identify up to 16 SmartIDs on the network,
as shown here. The SmartIDs will work through splitters, and multiple
SmartIDs can be detected simultaneously.
1. Register the SmartIDs.
If this is the first test with the SmartIDs, a warning message appears
asking you to register the SmartIDs.
If using the Bluetooth SmartID Plus, pair it with the
y
OneExpert and then connect to the SmartID Plus. (For more
information, refer to the
shipped with the SmartIDs.) The other SmartIDs need to be
registered as described below.
NOTE:
The registration applies to the SmartID that the OneExpert is
physically connected to. You will need to repeat the procedure
for each SmartID, connecting it directly to the OneExpert.
If the Registration doesn't automatically come up, select Actions, and then press
y
SmartID Registration.
Do one of the following:
y
- Use the up and down arrows to highlight the label letter for the SmartID and
then press OK.
- Press the letter for the SmartID.
222