11 Installation Information

11.1. ATTACHED ACCESSORIES

11.2. SELECT THE BEST LOCATION

11.2.1. INDOOR UNIT
∙ There should not be any heat source or steam near the unit.
∙ There should not be any obstacles blocking the air circulation.
∙ A place where air circulation in the room is good.
∙ A place where drainage can be easily done.
∙ A place where noise prevention is taken into consideration.
∙ Do not install the unit near the door way.
∙ Ensure the spaces indicated by arrows from the wall, ceiling or other obstacles.
∙ Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3m.
11.2.2. OUTDOOR UNIT
∙ If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not
obstructed.
∙ There should not be any animal or plant which could be affected by hot discharged air.
∙ Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
∙ Do not place any obstacles which may cause a short circuit of the discharged air.
11.2.3. PIPING LENGTH
The additional gas charge is unnecessary up to the Max. piping length.
Piping size
Common
Length (m)
Gas
Liquid
1/2"
1/4"
7
48
Max.
Max. Piping
Elevation (m)
Length (m)
5
10