CS-VG120KE / CU-VG120KE
9.3.

PROTECTION CONTROL FOR HEATING OPERATION

1. Intake Air Temperature Control
∙ When the intake air temperature is 10°C or above and remote control setting fan speed is less than Medium, the
compressor operates at 92Hz.
2. Outdoor Air Temperature Control
∙ The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram
below. This control will begin 50 seconds after the compressor starts.
3. High Pressure Control
∙ The compressor operating frequency is regulated in accordance to the indoor heat exchanger temperature.