Delay On Timer Control; Auto Restart Control - Panasonic CS-VG120KE Service Manual

Table of Contents

Advertisement

CS-VG120KE / CU-VG120KE

8.13. DELAY ON TIMER CONTROL

∙ When the Delay On Timer is set by using remote control, the unit will start to operate slightly earlier before the set time, so that
the room will nearly reach the set temperature by the On Timer set time.
∙ 60 minutes before the set time, the indoor fan operates at SLo and outdoor fan operates for 20 seconds to sample the indoor
intake air temperature and outdoor air temperature in order to determine the starting time for preparatory operation. (The Power
LED blinks during sampling.)
∙ The time of the preparatory operation will start before the On Timer set time.
1. Cooling/Soft Dry
2. Heating

8.14. AUTO RESTART CONTROL

∙ If there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous
operation mode and airflow direction. (Time Delay Safety Control is valid)
∙ Auto Restart Control is not available when Timer or Sleep Mode is set.
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-vg120ke

Table of Contents