CS-VG120KE / CU-VG120KE
4. To fix the Indoor Fan Motor, ensure that the Fan Motor securing
screw is positioned at the rear end and the Fan Motor lead wire is
positioned parallel to the Fan Motor. (Fig. 8)
12.4.3. Cross Flow Fan removal procedure
1. Remove the Indoor Fan Motor.
(Refer to the removal procedure of the Indoor Fan Motor.) (Fig. 9)
2. Remove the Air Discharge Grille by taking off the screws that hold the
Air Discharge Grille and then pull the Air Discharge Grille in a down and
forward direction. (Fig. 10)
58
Fig. 8
Fig. 9
Fig. 10