Outdoor Fan Control; Airflow Direction - Panasonic CS-VG120KE Service Manual

Table of Contents

Advertisement

8.8.

OUTDOOR FAN CONTROL

∙ Outdoor fan motor is controlled with 2 speeds. Fan is in operation when the compressor starts operation and stops 30 seconds
after compressor stops operation.
(During 80 seconds, Fan speed is at low).
8.9.

AIRFLOW DIRECTION

∙ Blade angle setting (Upper limit reference)
heating
Airflow direction auto
Airflow direction manual
Cooling
Airflow direction auto
Airflow direction manual
Dry
Airflow direction auto
Airflow direction manual
∙ Sitting angle
1. Airflow Direction Manual
By pressing the remote control airflow direction setting switch, the blade will move to the indicated angle (1, 2, 3, 4, 5) as shown
in the table. When the remote control OFF/ON switch is pressed, the blade will move to the Close position.
2. Airflow Direction Auto
By setting the airflow direction to AUTO, the blade swings up and down from 0°-37° during Cooling and Soft Dry operation.
During Heating operation, the blade angle will shift according to the indoor heat exchanger temperature as shown below:
Fan Speed
Cooling-Soft Dry
High
Over 45Hz
Low
Below 45Hz
Operation
Indoor heat exchanger
temperature
-
-
Anti-dew formation control
-
Anti-dew formation control
-
Anti-dew formation control
-
Anti-dew formation control
Stop
Compressor Operating Frequency
Heating
Over 73Hz
Below 73Hz
1
A
B
C
-
18°
11.5°
11.5°
27
CS-VG120KE / CU-VG120KE
Blade angle
2
3
4
14°
61°
29.4°
45.1°
0° - 37°
3° - 37°
18°
28°
20°
28.5°
0° - 37°
3° - 37°
18°
28°
20°
28.5°
138°
5
61°
37°
37°
37°
37°