12.4.6. Inspection Method for the Outdoor Unit
1. Remove the control box. (Two screws)
2. Remove the particular plate.
3. Remove the control box cover.
4. Remove the front panel. (Four screws) (Fig.17)
WARNING:
∙ Be sure to return the wiring to its original position.
∙ There are many high voltage components within the heat
sink cover so never touch the interior during operation.
Wait at least two mines after power has been turned OFF.
5. Remove the control box. (Tow screws)
6. Remove the control box cover.
7. Remove the Power transistor module. (Two screws) (Fig.18)
61
CS-VG120KE / CU-VG120KE
Fig. 17
Fig. 18