CS-G90KE
Installation Information
Attached accessories
No.
Accessories part
Installation plate
1
Installation plate fixing screw
2
Remote control
3
Battery
4
Air purifying filter
5
Accessories: Flaring piping kit
CZ-3F5, 7AEN (CS-G90KE)
CZ-4F5, 7AEN (CS-G120KE)
SELECT THE BEST LOCATION
•
There should not be any heat source or steam near the unit.
•
There should not be any obstacles blocking the air circulation.
•
A place where air circulation in the room is good.
•
A place where drainage can be easily done.
•
A place where noise prevention is taken into consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
•
Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3 m.
•
There should not be any animal or plant which could be affected by hot air discharged.
•
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
•
Do not place any obstacles which may cause a short circuit of the discharged air.
•
If piping length is over the rated length, additional refrigerant should be added as shown in the table.
MODEL
G90KE
G120KE
Qty.
No.
Accessories part
Drain elbow
6
1
Clamping cover of piping
7
6
Vinyl tape
8
1
Vinyl tape
2
9
2
INDOOR UNIT
OUTDOOR UNIT
Piping size
Rated
Length
Gas
Liquid
3/8"
1/4"
5
1/2"
1/4"
5
– 49 –
Qty.
1
1
3
1
Max.
Max.
Additional
Piping
Elevation
Refrigerant
Length
(m)
(g/m)
(m)
5
7
–
5
7
–