Panasonic CS-VG120KE Service Manual page 23

Table of Contents

Advertisement

Setting temp °C
18 and below
19 - 22
23 - 26
27 and above
∙ When the operation mode is changed over, the value for t1, t2 and t3 are shifted as follows:
Cooling/Soft dry → Heating: -2°C
Heating → Cooling/Soft dry: +2°C
∙ When the indoor intake air temperature is lower than 16°C, heating operation is immediately started.
∙ When the outdoor air temperature is more than 25°C, and the intake air temperature is over 16°C, cooling operation is
immediately started.
∙ The operation mode is judged every 30 minutes.
∙ When the operation mode (Heating, Cooling or Soft Dry) is decided, the internal setting temperature will shift as shown below:
T1
T2
T3
Note:
Base temperature for T1 is 29 °C
+10
+8
-5
+8
+7
-7
Base temperature for T2 is 27 °C
+7
+6
-7
Base temperature for T3 is 21 °C
+6
+5
-8